16/36
2.11 The NEXEDGE TRS Interface
This interface allows you to connect to a NEXEDGE repeater via IP.
Explanation of Fields
•
Name
o
The name of the channel on FlexGate.
•
Console ID
o
The console ID as configured in the NEXEDGE Trunked System.
•
System Code
o
The system code as configured in the NEXEDGE Trunked System.
This is a unique ID assigned to each system (1 to 131070.
•
Site Code
o
The site code, or “Home Site Number” as configured in the
NEXEDGE Trunked System.
•
Station Type
o
This is used to distinguish between registering to a
talk group or an individual.
•
Station Name
o
Specific name given to the station.
•
Station ID
o
Specific Station ID number.
•
Network Category
o
The network category as configured in the NEXEDGE System.
•
Is Ultra Narrow
o
When checked, the NEXEDGE system is configured for
ultra-narrow channel spacing. Otherwise, it is narrow band only.
•
Radio System Address
o
The IP address of the home site and is usually associated with
the smallest channel number at a home site.
•
Bind To Address
o
The IP address of the network adapter that is associated with
the NEXEDGE Trunked System.
•
Jitter Buffer Depth
o
For advanced use only. Default value is 60.
•
Reregister Time (min)
o
The reregister time prevents the NEXEDGE System from
deregistering for being idle.
•
Emergency alert Relay
o
This will be the relay module that will associate with the radio when
the emergency alert is triggered.
•
Emergency Alert Relay #
o
This will be the relay number associated with the relay when the
emergency alert is triggered.
•
Emergency Alert Time to Hold
o
This is an adjustable amount of time from 1 second
to 5 minutes
to have the relay active during an emergency alert.
•
Encryption Type
o
If encryption is enabled in the NXDN system change to scramble.
•
Key ID
o
Key ID must be set to the Key ID programmed in the NXDN system.
•
Key Data
o
Key data must be set to the same Key Data value as in the NXDN
system.
Figure 2-11: The configuration screen for the