Stand 25.05.2011
Seite 24
Operating instruction TAXON
Page 24
of 42
4.5
Stand emptying
To empty the container when standing, proceed as follows:
•
Pay attention to all warning information like the ones described in chapter 4.
•
Place the carrier vehicle on an even, solid ground.
Ensure that the handbrake is put on.
•
The emptying when standing should be carried out, as a rule, at a salt loading station, where the
spreading material will be reused.
•
Switch on the vehicle hydraulic system.
• Switch
off the control panel.
•
Go to the rear of the spreader and open the lid of the device box.
Here, the hydraulic block with the respective manual emergency valves is
installed on the side. .
•
Stand on the side with a distance to the spreading disk before you
operate the hydraulic control unit!
- Danger of injury from the rotating spreading disk
- Danger of dirtying the clothing from thrown off spreading material
•
Slowly open the manual valve of “ Manual emergency operation Salt”.
Now, the auger starts rotating and salt fl ows onto the spreading disk.
•
Then open the manual operation valve of “Manual emergency operation Disk” (About stage 3). Due
to the very slow disk rotation, the spreading material will be discharged only on a very narrow area.
•
After emptying the spreading container reset all manual operation valves to “Null” (ZERO).
•
Close the lid of the device box.
Hydraulic block SRCA