No. Message in display
Meaning and possible cause
50 Idle meas. impossible. EMC control
deactivated!
PTO speed not permanently stable
51 Hopper empty!
The kg level sensor reports “empty.” The
entered value is undercut.
52 Error at hopper cover
The position of the hopper cover could not
be reached.
•
Blockage
•
Defective actuator
53 Defect at hopper cover
The hopper cover actuator cannot reach the
target value for the movement.
•
Blockage
•
Defective actuator
54 Change TELIMAT position!
The TELIMAT position does not correspond to
the state notified by GPS Control.
72 Error at SpreadLight
Power supply is too high; the operating lights
will be switched off.
73 Error at SpreadLight
Overload
74 Defect at SpreadLight
Connection error
•
Defective cable
•
Loose plug connector
93 This disc type requires a modification on the
TELIMAT device. Please follow the mounting
instructions!
Spreading disc S1 is installed and the machine
is equipped with TELIMAT. Spreading errors
possible during border spreading
•
This spreading disc type requires
conversion of the TELIMAT device.
94 Error at border spreading equip
Alarm for the GSE sensor. This error message
is displayed if the GSE status is not detected
for more than 5 seconds.
6. Alarm messages and possible causes
QUANTRON-A AXIS/MDS
5902662