The specified PTO speed is preset in the control unit to 540 rpm as a standard factory setting. If you
want to specify a different PTO speed, you must change the saved value in the control unit.
u
Access the menu Fertiliser settings > PTO.
u
Enter the speed in rpm.
The Fertilizer settings window is displayed with the new PTO speed.
4.6.7
Disc type
For optimal empty run measurement, check the correct input in the Fertiliser settings menu.
•
The settings in the Spreading disc and PTO menu items must correspond to the actual
settings of your machine.
The mounted spreading disc type is preset in the control unit as a standard factory setting. If you have
mounted different spreading discs on your machine, you must enter the correct type in your control
unit.
u
Access the menu Fertiliser settings > Spreading disc.
u
Activate the spreading disc type in the selection list.
The Fertiliser settings window is displayed with the new spreading disc type.
4.6.8
Boundary spreading quantity
In this menu, the application rate reduction for the TELIMAT boundary spreading unit can be set (as a
percentage value). This setting is used for the activation of the boundary spreading function via the
TELIMAT-Sensor sensor or the T key.
We recommend reducing the quantity on the boundary spreading side by 20 %.
Entering the boundary spreading application rate:
u
Access the menu Fertiliser settings > Bound.quantity (%).
u
Enter the value in the input field and confirm.
The Fertiliser settings window is displayed with the new boundary spreading application rate.
4. Operation
QUANTRON-A AXIS/MDS
5902662
53