Selecting a fertilizer chart
u
Access the menu Fertiliser settings > Fertiliser chart.
u
Select the desired fertilizer chart.
The display shows the selection window.
u
Select the option Open and back to fertiliser settings.
The Fertiliser settings menu is displayed and the selected element is loaded into the fertilizer settings
as the active fertilizer chart.
When selecting an existing fertilizer chart, all values in the Fertiliser settings menu will be
overwritten with the stored values obtained from the selected fertilizer chart, including the drop
point and the PTO speed.
•
Machine with electrical drop point actuators
: The machine control unit will move the
actuators of the drop point to the value stored in the fertilizer chart.
Copying an existing fertilizer chart
u
Select the desired fertilizer chart.
The display shows the selection window.
u
Select the option Copy element.
A copy of the fertilizer chart is now in the first free position on the list.
Deleting an existing fertilizer chart
u
Select the desired fertilizer chart.
The display shows the selection window.
The active fertilizer chart cannot be deleted.
u
Select the option Delete element.
The fertilizer chart is deleted from the list.
4.6.12
Calculate VariSpread
The VariSpread section assistant automatically calculates the section steps in the background. Your
inputs for the working width and the drop point in the first pages of the fertilizer settings provide the
basis for this.
4. Operation
QUANTRON-A AXIS/MDS
5902662