Operation QUANTRON-A
4
36
4.3.2
Displaying the remaining quantity
In the
Rest (kg, ha, m)
menu, you can check or enter the
remaining quantity
in the hopper.
The menu shows the possible
area (ha)
and
distance (m)
which can still be
spread with the remaining fertiliser quantity. Both displays are calculated based
on the following values:
Fertiliser settings,
Input in the
remaining quantity
input field,
Application rate,
Working width.
Figure 4.4:
Rest (kg, ha, m) menu
[1] Remaining material input field
[2] Application rate (display field from fertiliser settings)
[3] Working width (display field from fertiliser settings)
[4] Display of possible area that can be spread with the remaining quantity
[5] Display of the possible distance that can be spread with the remaining quantity
NOTICE
The current loading weight can be determined only by weighing in the
weighing
spreader
.
In all other spreaders, the remaining fertiliser quantity is calculated from the
fertiliser and machine settings and the driving signal, and the filled quantity must
be entered manually (see below).
The values for
application rate
and
working width
cannot be changed in this
menu. They are provided here for information only.
1
2
4
5
3