Commissioning
73
7
Figure 7.25:
Layout of the collecting vessels
Make sure that the collecting vessels are placed on level ground. Collecting
vessels set at an angle can cause measuring errors (see image above).
Carry out the calibration test (see chapter B.6 of the corresponding machine
type).
Adjust and fix the metering slides on the right and left-hand side (see chapter
B.4 of the corresponding machine type).
Run the spreading test with the determined open position for operation:
Forward speed:
3 - 4 km/h
.
Spread along the tramlines 1-3 one after the other.
Open the metering slide
10 m in front of
the collecting vessels.
Close the metering slides approx.
30 m behind
the collecting vessels.
NOTICE
If the quantity collected in the collecting vessels is insufficient, repeat the run.
Do not change the adjustment of the metering slides.