No. Message in display
Meaning and possible cause
89 Disc speed too high
Alarm of the spreading disc sensor
•
The maximum RPM is reached.
•
The set RPM exceeds the maximum
admissible value.
90 AXMAT-Stop
The AXMAT function is automatically
deactivated and no longer regulates.
•
More than 2 sensors are reporting an
error.
•
Communication error
93 This disc type requires amodification on
theTELIMAT device.Please follow themounting
instructions!
Spreading disc S1 is installed and the machine
is equipped with TELIMAT. Spreading errors
possible during border spreading
•
This spreading disc type requires
conversion of the TELIMAT device.
6.2
Fault/alarm
An alarm message is displayed with a red frame and with a warning symbol.
Fig. 50: Alarm message (example)
6. Alarm messages and possible causes
98
5902180-h-gb-
AXIS EMC ISOBUS