The TELIMAT option is preset for the control unit at the factory!
TELIMAT with hydraulic remote control
The TELIMAT unit is hydraulically moved to its working or idle position. The TELIMAT unit can be
activated or deactivated by pressing the border spreading key. Depending on the position, the display
shows or hides the
TELIMAT icon
.
TELIMAT with hydraulic remote control and TELIMAT sensors
If TELIMAT sensors are connected and activated, the
TELIMAT icon
is shown on the display when
the TELIMAT border spreading unit is hydraulically moved into its operating position.
If the TELIMAT unit is moved back to the idle position, the
TELIMAT icon
is hidden again. The
sensors monitor the TELIMAT adjustment and automatically activate or deactivate the TELIMAT unit.
The limited border spreading key has no function with this option.
If the status of the TELIMAT unit cannot be detected for more than 5 seconds, alarm message 14 will
be displayed; see
6.1 Meaning of the alarm messages
.
5.4
Electrical TELIMAT unit
For AXIS-M 50.2
CAUTION!
Risk of injury due to automatic adjustment of the TELIMAT unit!
By pressing the
TELIMAT
, the unit automatically moves to the boundary spreading position by
means of an electrical actuating cylinder. This may cause injury and property damages.
▶
Before pressing the
TELIMAT
key, make sure that nobody is present in the hazard zone of
the machine.
5. Spreading operation
AXIS EMC ISOBUS
5902180-h-gb-
75