4.4.8
Limited border spreading mode
only
AXIS-H
In this menu, you can select a suitable spreading mode at the field boundary.
Fig. 14: Limited border spreading mode setting values
[1]
Full border spreading
[2]
Limited border spreading
u
Access the menu Fertiliser settings.
u
Switch to tab 2.
u
Select limited border spreading mode Full bord. or Limited bd.
Only the values of the bottom 3 setting menus will adapt to the selected mode. The menu names
remain unchanged.
u
If required, adjust the RPM, Drop point or quantity reduction in accordance with the information
provided in the fertilizer chart.
4.4.9
Border spreading application rate
In this menu, you can reduce quantity value (as a percentage). This setting is used for the activation of
the limited border spreading function and/or the TELIMAT unit (AXIS-M only).
We recommend reducing the quantity on the boundary spreading side by 20 %.
Entering the border spreading application rate:
u
Access the menu Fertiliser settings > Bound.quantity (%).
u
Enter the value in the input field and confirm.
The Fertiliser settings window is displayed with the new border spreading application rate.
4. Operation
42
5902180-h-gb-
AXIS EMC ISOBUS