-96-
Fault tree: Changing pcb / changing EEPROM / Fault "E1"
C
hanging
pcb
Software
update
Unit
displays
"E1"
New
EEPROM
to
be
connected
to
pcb
with
unknown
S
W
version
or
software
version
before
C
1-06-05
Isolate
unit
from
power
supply
(Disconnect
control
fuses)
Fault
type:
1
Fault
type:
2
or
3
Reconnect
unit
to
power
supply
(reconnect
control
fuses)
Replace
pcb,
do
NOT
connect
EEPROM
as
software
version
on
new
pcb
might
not
be
known
NOTE:
Do
NOT
connect
replacement
EEPROM
to
pcb
as
software
version
on
pcb
might
be
too
old
!
New
EEPROM
might
be
damaged
again
!
Update
software
to
C
1-06-05
or
later
Reconnect
unit
to
power
supply
(reconnect
control
fuses)
OK
"E1"
is
still
displayed
Fault
type
2
or
3
C
ontact
Rational
Service
OK
Fault
type:
1
Fault
type:
2
Fault
type:
3
Isolate
unit
from
power
supply
(Disconnect
control
fuses)
Reconnect
EEPROM
Update
software
to
C
1-06-05
or
later
Software
update
OK
Summary of Contents for SCC Line
Page 35: ...35 S S C C SCC Control Panel Notes...
Page 41: ...41 S S C C Notes...
Page 43: ...43 S S C C Notes...
Page 47: ...47 S S C C Notes...
Page 55: ...55 S S C C Notes...
Page 63: ...63 S S C C Notes...
Page 78: ...78 S S C C M6 M6 M6 M6 S12 S12 1 2 3 4 5 6 Control Drain Valve 54 00 357 Notes...
Page 79: ...79 S S C C Notes...
Page 81: ...81 S S C C Notes...
Page 91: ...91 S S C C Notes...
Page 93: ...S 93 COMMON Notes...
Page 107: ...S 107 COMMON Notes...
Page 109: ...S 109 COMMON Notes...
Page 128: ...S 128 COMMON Notes...
Page 129: ...S 129 COMMON Notes...
Page 183: ...S 129 COMMON Notes...