-124-
S
Fault List CM
Fault tree: Changing pcb / changing EEPROM / Fault "E1"
Changing pcb
Software
update
Unit displays
"E1"
New EEPROM to be connected to
pcb with unknown SW version or
software version before C1-06-05
Isolate unit from power supply
(Disconnect control fuses)
Fault type: 1
Fault type:
2 or 3
Reconnect unit to power supply
(reconnect control fuses)
Replace pcb, do NOT connect
EEPROM as software version on new
pcb might not be known
NOTE:
Do NOT connect replacement EEPROM
to pcb as software version on pcb might
be too old!
New EEPROM might be
damaged again!
Update software to C1-06-05 or later
Reconnect unit to power supply
(reconnect control fuses)
OK
"E1" is still
displayed
Fault type 2 or 3
Contact Rational
Service
OK
Fault type: 1
Fault type: 2
Fault type: 3
Isolate unit from power supply
(Disconnect control fuses)
Reconnect EEPROM
Update software to
C1-06-05 or later
Software
update
OK
Summary of Contents for SCC Line
Page 35: ...35 S S C C SCC Control Panel Notes...
Page 41: ...41 S S C C Notes...
Page 43: ...43 S S C C Notes...
Page 47: ...47 S S C C Notes...
Page 55: ...55 S S C C Notes...
Page 63: ...63 S S C C Notes...
Page 78: ...78 S S C C M6 M6 M6 M6 S12 S12 1 2 3 4 5 6 Control Drain Valve 54 00 357 Notes...
Page 79: ...79 S S C C Notes...
Page 81: ...81 S S C C Notes...
Page 91: ...91 S S C C Notes...
Page 93: ...S 93 COMMON Notes...
Page 107: ...S 107 COMMON Notes...
Page 109: ...S 109 COMMON Notes...
Page 128: ...S 128 COMMON Notes...
Page 129: ...S 129 COMMON Notes...
Page 183: ...S 129 COMMON Notes...