Changing Gas blower speed (MAX, Start, MIN rpm): CM gas from 04-2004
(as from Software C-06-03):
Note:
This setting shall ONLY be done by specially trained and
RATIONAL approved technicians.
SE
A)
B)
C)
D)
E)
F)
G)
H)
I)
J)
K)
L)
M)
N)
O)
P)
Q)
6250
Open
cabinet
door
Select
any
mode
Open
control
panel
Set DIP switch 1 on PCB to „ON“ position
With timer dial select: „SE“ = Settings
Activate „Settings“ by pressing core temperature key; display
changes
to
„SE1“
With timer dial select: SE9
Activate position SE9 „blower motor steam MIN“ rpm with timer
key
Timer display shows stored value from EEPROM, i.e. 6250
While pressing timer key blower speed can be adjusted with timer
dial by + / -10%
Note: Adjust steps in increments of 60rpm only!
Changed rpm will be shown in timer display.
Confi rm new rpm setting with core temperature key
(keep timer key pressed)
Release timer key
Repeat steps F) - J) at SE10 „blower motor steam Start“ rpm
and at SE11 „blower motor steam MAX“ rpm“
Adjust steps in increments of 60rpm only!
Repeat steps F) - J) at
SE12 „blower motor hot air, top MIN“ rpm,
SE13 „blower motor hot air, top Start“ rpm, and
SE14 „blower motor hot air, top MAX“ rpm.
Adjust steps in increments of 60rpm only!
CM 201 and 202: Repeat steps F) - J) at
SE15 „blower motor hot air, bottom MIN“ rpm,
SE16 „blower motor hot air, bottom Start“ rpm, and
SE17 „blower motor hot air, bottom MAX“ rpm.
Adjust steps in increments of 60rpm only!
De-activate selected package by pressing core temperature key;
To exit service program set DIP switch 1 to „OFF“ position
To store the new blower speed setting the unit must be switched
OFF
and
ON
again.
Perform fl ue gas analysis in function test at F21, F24, F27
as well as the check of CO
2
values at F19, F22, F25
1
2
3
4
on
1
2
3
4
on
Summary of Contents for SCC Line
Page 35: ...35 S S C C SCC Control Panel Notes...
Page 41: ...41 S S C C Notes...
Page 43: ...43 S S C C Notes...
Page 47: ...47 S S C C Notes...
Page 55: ...55 S S C C Notes...
Page 63: ...63 S S C C Notes...
Page 78: ...78 S S C C M6 M6 M6 M6 S12 S12 1 2 3 4 5 6 Control Drain Valve 54 00 357 Notes...
Page 79: ...79 S S C C Notes...
Page 81: ...81 S S C C Notes...
Page 91: ...91 S S C C Notes...
Page 93: ...S 93 COMMON Notes...
Page 107: ...S 107 COMMON Notes...
Page 109: ...S 109 COMMON Notes...
Page 128: ...S 128 COMMON Notes...
Page 129: ...S 129 COMMON Notes...
Page 183: ...S 129 COMMON Notes...