-46-
S
S
C
C
Motor for SCC / CM
Jumper 40.01.581 is used on fl oor model 201 and 202 for top position motor only!
Jumper is not used on models 61 - 102 with one motor only! (Service 34 will be shown!)
LED
Jumper
Reason
1x
Motor doesn’t start, no changing
signal
from
hallsensor
2x
Voltage too low on motor pcb
3x
Voltage too high on motor pcb
4x rpm
measurement
defective
5x
Motor pcb temperature >105°C
6x Supply
voltage
<80V
7x
Motor pcb defective
8x
Motor pcb defective
LED code fan motor SCC and CM from 04/2004
Remedy
Check for motor blockage or change mo-
tor.
Check supply voltage or
change motor.
Check supply voltage or
change motor.
Change motor.
Check cooling system (cooling fan, air
intake fi lter), otherwise change motor
Check power supply
(F1-F2)
Change motor.
Change motor.