Before you call Service:
82 / 85
of fat are cooked frequently or if the
drop on the outlet pipe is too shallow.
To remedy: Run the outlet pipe as
described in the installation instructions.
The unit does not
indicate a function
after it is switched on
External main switch is
switched off
Switch on at the main switch
Fuse on the premises’
distribution board has
tripped
Check the fuses on the premises’
distribution board
The ambient
temperature after
switching the unit off
remained below 5 °C
(41 °F) for a long time
Heat the cooking cabinet to above 20
°C (68 °F). The appliance must only
be used in frost-free conditions (see
installation instructions).
Unit displays “CHnG
FILt”
The air filter is soiled.
Please replace the air filter. See also
the “Maintenance” section. Press the
“cooking time” button to acknowledge
the message.
The gas appliance
indicates “CHnG PoL”.
The power supply is
not connected with the
correct polarity.
If the gas unit is connected to a socket,
remove the connector and turn through
180°.
Have an electrician permanently
connect the unit with the correct polarity
(without a connector).
Gas appliance
constantly displays
Reset “rES”.
The gas supply to the
unit is interrupted.
Open the gas valve
Switch on the ventilation cover
The gas pressure is
too low
Have the gas supply to the unit checked
Flashing cooking
mode display
The cooking cabinet is
too hot
Use Cool Down to cool the cooking
cabinet (see the “cool down” section of
the manual).
Summary of Contents for CombiMaster Plus 61
Page 1: ...Original operating instructions CombiMaster Plus ...
Page 83: ...EU Declaration of Conformity for electrical appliances 83 85 ...
Page 84: ...EU Declaration of Conformity for gas appliances 84 85 ...
Page 85: ... ...
Page 86: ... ...
Page 87: ... ...
Page 88: ...80 05 001 V 05 MDS Ad 02 16 ...