Page 2: ...atio Electric B V Ambachtsstraat 12 NL 3861 RH Nijkerk The Netherlands Tel 31 33 2452360 info ratio nl www ratio electric com Thank you for choosing Ratio Electric Solar Box UK English Original EV081...

Page 3: ...multiple languages The original manual is written in UK English All other language versions are translations of the original manual Copyright The content of this manual is protected by copyright and...

Page 4: ...e in the consumer unit 14 5 3 Install the sensorbox in the consumer unit 15 5 4 Mount the charger to a wall 18 5 5 Connect the power cable to the charger 20 5 6 Install the data cable in the charger24...

Page 5: ...warnings that may result in injury when ignored Each safety warning is indicated with a signal word The signal word corresponds with the level of risk of the described hazardous situation see the tabl...

Page 6: ...ns or defects of the product that impose safety risks Failure to carry out the inspections and maintenance operations as described in this manual Unauthorized removal or modification of parts or safet...

Page 7: ...when used around children Do not put fingers into the electric vehicle connector Do not use this product if the flexible power cord or EV cable are frayed have broken insulation or any other signs of...

Page 8: ...he vehicle is equipped with a conductive charge port Use of any adaptors is not allowed with this product Only use certified type 1 or type 2 charging cables with this product NOTICE Do not drop the p...

Page 9: ...ges the EV using a set maximum power in Amps I Max Note This mode does not have a load balancing feature to prevent the grid connection from being overloaded Smart The charger only charges the EV when...

Page 10: ...Phase 1 L1 CT clamp input 2 Phase 2 L2 CT clamp input 3 Phase 3 L3 CT clamp input 4 Mains input 5 Data cable terminal block connector 6 Status LED 7 CT clamp 3 for 3 phase installation The mains input...

Page 11: ...5 Protection against electric shock Class I Residual current detection DC 6mA Dimensions 400 mm 250 mm 105 mm Housing PC ABS VO Weight 4 kg incl cable IP Protection rating IP54 rain tight Altitude Up...

Page 12: ...the original packaging or suitable replacement packaging that provides adequate protection from vibrations bumps moisture dust and debris Be careful not to drop the product and prevent it from moving...

Page 13: ...heck the contents 1 Open the box and remove the contents 2 Place all parts on an empty surface to avoid losing any parts 3 Check if all parts are present and undamaged using the overview below In case...

Page 14: ...40 A B C characteristic Residual Current Device RCD 30 mA Type A Data cable Shielded UTP cable or 4 0 25 mm2 cable max 25 m cable length 5 2 Install the power cable in the consumer unit 1 Switch off...

Page 15: ...ve If the mains plug is inserted upside down the measurements of the sensorbox will be inaccurate Check the markings on the sensorbox for the correct orientation 1 L N MAINS 2 3 1 L N MAINS 2 3 N 1 L...

Page 16: ...r supply L Note Make sure the arrow on the current transformer points towards the entry point of the main power grid See the image below for more information on the correct mounting location of the CT...

Page 17: ...grid Note It is crucial for the functioning of the charger that you insert the current transformers into the correct input 8 Insert the 3 5 mm jacks of the current transformers to the L2 and L3 input...

Page 18: ...e you have purchased the optional pole for the charger check the installation manual provided with the pole for mounting instructions 150 mm 225 mm 80 100 cm 1 Tape the provided drilling template to t...

Page 19: ...arger is level Use a spirit level 3 Mark the locations of the holes in the charger housing on the wall 4 Carefully remove the charger and lay it on a flat stable and dry surface 5 Drill the holes in t...

Page 20: ...to the charger TX10 1 Remove the five Torx screws from the housing lid Use a size TX10 screwdriver 2 Move the housing lid to the side to access the inner circuitry of the product 3 Carefully remove th...

Page 21: ...ve the sealing nut from the cable gland 5 Insert the cable gland through the left cable inlet 6 Secure the cable gland with the locknut 7 Guide the power cable through the sealing nut 8 Guide the powe...

Page 22: ...Box Manual 7 mm 80 mm 9 Strip the wires of the power cable 10 Connect the stripped wires to the correct terminals of the left terminal block L1 Brown L2 Gray L3 Black N Blue Earth Green Yellow for 3...

Page 23: ...c com 11 Secure the wires to the terminals using a voltage tester screwdriver 12 Gently pull the excess power cable out of the charger 13 Secure the power cable in place by tightening the sealing nut...

Page 24: ...Electric Solar Box Manual 5 6 Install the data cable in the charger 1 Remove the terminal block connector from the charger 2 Carefully remove the centre cable inlet cover Use a flathead screwdriver an...

Page 25: ...e rubber cable grommet using a screwdriver 4 Insert the rubber cable grommet into the centre cable inlet 5 Guide the data cable through the rubber grommet 40 mm 6 Strip the wires of the data cable 7 T...

Page 26: ...s to the terminals Use a voltage tester screwdriver 11 Insert the terminal block connector into the charger 12 Gently pull the excess ethernet cable out of the charger If you have purchased a single c...

Page 27: ...terminal connector of the existing data cable from the charger 3 Guide the second data cable alongside the existing data cable through the rubber grommet 40 mm 40 mm 4 Strip the wires of the data cabl...

Page 28: ...ic Solar Box Manual 7 Insert the wires into the terminal block connector alongside the existing wires 8 Secure the wires to the terminals using screwdriver 9 Insert the terminal block connector back i...

Page 29: ...remove the centre cable inlet cover Use a flathead screwdriver and hammer 2 Punch a hole in the centre of the rubber cable grommet using a screwdriver 3 Insert the rubber cable grommet into the centre...

Page 30: ...he three solid coloured wires 7 Remove the unused wires 8 Insert the wires into the terminal block connector in the exact same order as in the main controller charger 9 Secure the wires to the termina...

Page 31: ...neutral and earthing wires are properly connected Check if the data cables are wired correctly and the order of the coloured wires matches on both sides Check if all cables are free of damage and are...

Page 32: ...tio Electric Solar Box Manual 5 9 Finish the installation TX10 1 Secure the housing lid in place with the five Torx screws using a size TX10 screwdriver 2 Click the front cover ring on the charger hou...

Page 33: ...ratio electric com 3 Place the four screw caps to cover the mounting screws Congratulations you have finished installing the charger Before the charger is ready for use you must first commission the c...

Page 34: ...figuration of the charger NOTICE The INSTALLER SETUP menu should only be accessed by a qualified technician In this menu you can adjust settings that if entered incorrectly could damage the installati...

Page 35: ...charger is set to a unique SUB number Note Make sure only one of the interconnected chargers is set to Main Controller Note Pure Solar mode is not compatible with power sharing If you enable power sha...

Page 36: ...nOffDelay Set a delay time for the charger to stop charging after net power generation is no longer detected Range 15 min 60 min ERR MEMORY Check for error message history EXIT SETUP Save your changes...

Page 37: ...n grid supply 3 Car icon Connected EV detected 4 Power sharing role indicator MN Main controller SUB1 sub charger no 1 SUB2 sub charger no 2 SUB3 sub charger no 3 The display has multiple screens Use...

Page 38: ...ecent charging sessions Et 1 0 0 kWh Et 2 0 0 kWh Et 3 0 0 kWh Et 4 0 0 kWh Et 5 0 0 kWh 7 2 Start charging 7 2 1 Using the selected charge mode 1 Plug your charging cable into the socket of the charg...

Page 39: ...lights up blue to indicate that a charging session is in progress Note The charging cable is locked during charging and cannot be removed until the charging session has ended 7 2 2 Using the Charge no...

Page 40: ...3 1 Charging paused In case there is less than 6A available on the main grid the charging session will automatically be paused Switch off any power demanding devices or wait until more than 6A power i...

Page 41: ...wing settings CHG MODE Select the desired charge mode Available options Basic Smart Smart Solar Pure Solar Default Basic Note See chapter 2 for more information on the charge modes I MIN Set the minim...

Page 42: ...ution 100 CP error faulty values or short circuited Possible causes Damaged charging cable Dirty connectors Issue originating from the EV Switch off the power to the main grid Clean the connector s of...

Page 43: ...e charge cable is properly inserted and locked into your EV If you cannot find the reason why your charger is not working properly please contact your local reseller or Ratio Electric B V 10 Maintenan...

Page 44: ...eplacement products may be either new or reconditioned at Ratio Electric B V discretion This limited Carry In Warranty does not include service to repair damage from improper installation improper con...

Page 45: ...ever there are some instances where high powered radio signals or nearby RF producing equipment such as digital phones RF communications equipment etc could affect operation If interference to your ch...

Page 46: ......

Page 47: ......

Page 48: ...Ratio Electric B V Ambachtsstraat 12 NL 3861 RH Nijkerk The Netherlands Tel 31 33 2452360 info ratio nl www ratio electric com For more information see the extended manual online...