8. Settings
To enter the USER SETUP menu, press and hold
for five seconds.
USER SETUP
<- CHG MODE ->
Note:
It is not possible to enter the settings menu during a charging session.
Note:
After 2 minutes of inactivity, the display automatically returns to the Home screen
without saving any changes.
Use & to switch between the settings and press to enter the selected setting.
You can configure the following settings:
CHG MODE
Select the desired charge mode.
Available options: Basic, Smart, Smart Solar, Pure Solar.
Default: Basic.
Note:
See chapter 2 for more information on the charge modes.
I-MIN
Set the minimum required charging power of the charger.
Range: 5A - 16A.
Default: 6A.
I-MAX
Set the maximum allowed charging power of the charger.
Range: 7A – 32A.
Default: 16 or 32A, depending on the charger model.
Imin smSolar
Set the minimum required charging power of the charger for the Smart
Solar charge mode
Range: 6A – 10A.
Imin puSolar
Set the minimum required charging power of the charger for the Pure
Solar charge mode.
Range: 6A – 16A.