CCR Settings for RATIO iX3M Tech+ & iX3M Reb
To navigate the menu follow the instructions in the picture on the left.
CCR MODE:
ON= CCR enabled in scuba mode. /// OFF= Deactivated.
SETPOINT LOW:
Range 0.40 a 1.60. It is the starting setpoint.
DEPTH 1:
Automatic switch from SETPOINT LOW to SETPOINT MID and vice versa.
SETPOINT MED:
Range 0.40 a 1.60 (Step 0.05)
DEPTH 2:
Automatic switch from SETPOINT MID to SETPOINT HIGH and vice versa.
SETPOINT HIGH:
Range 0.40 a 1.60 (Step 0.05)
SETPOINT MODE:
AUTO
= During the dive the iX3M will automatically switch from SETPOINT
LOW
to
SETPOINT
MID
at
DEPTH 1
, from SETPOINT
MID
to SETPOINT
HIGH
at
DEPTH 2
and (during
the ascending) from SETPOINT
HIGH
to SETPOINT
MID
at
DEPTH 2
and from SETPOINT
MID
to
SETPOINT
LOW
at
DEPTH 1.
MAN
=
The Set Point have to be managed manually during the dive.
(See “Change the set point during a dive” on this manual)
During the dive you can switch from AUTO to MAN,
During the dive you can NOT switch from MAN to AUTO.
(See “Change the set point during a dive” on this manual)
Attention
: Enable the Rebreather mode (CCR) only for dives with rebreather.
The CCR mode is not suitable for dives in open circuit!
Attention
: Diving with Rebreather requires a specific training !!!
Diving with Rebreather without a suitable training or without the due caution can cause injuries or death.
Refer to your Rebreather instructor to get instructions on how to set the SET POINT
.
CCR SETTINgS
CCR MODE:
SETPOINT LOW:
DEPTH 1:
SETPOINT MED:
DEPTH 2:
SETPOINT HIGH:
SETPOINT MODE:
b
A
C
D
ExIT
NExT
ENTRY
+
_
OFF
0.70
20 M
1.00
50 M
1.40
AUTO