11. AIR PRESSURE GAUGE (OPTION)
The pneumatic scissors must be necessarily fed with
lubricated air with a pressure of 4-6 bar.
Rasor
®
offers, as option, a reduction unit filter with a
pressure gauge already calibrated with the quantity
of oil to be delivered.
The unit shown in picture 7 is made up of:
1 - pressure reducer;
2 - valve to drain the condensate;
3 - drip-feed oiler unit;
4 - oil tank;
5 - pressure gauge;
6 - condensate tank;
7 - pipe fitting to connect the quick connection to
the network;
8 - pipe fitting to connect the quick connection to the scissor.
For the use and maintenance read the instruction sheet supplied with the filter.
12. SHARPENER ADJUSTMENT
After using the machine for some hours without
interruption, or if the machine cutting capacity is reduced,
it is necessary to sharpen the blade.
To carry out this operation, start the blade and press
sharpener “2” on the blade itself (by means of push button
“1”, as shown in picture 8) for 3-4 seconds. Repeat this
operation 2-3 times.
The sharpener can slide along its seat (see picture 9) in
order to vary the sharpening angle. If the blade, after
various sharpening operations, has a chamfer (sharp
perimeter) with an excessive length (higher than 1.5 mm),
it is necessary to slightly move the sharpener away from
the blade. In order to do this, it is sufficient to slightly
loosen the screws without removing them, making the
sharpener slide toward direction “A”, and then tighten
the two screws again.