10.4 Ladder Dia
g
ram
10.5 Electrical Connection to the Burner
Conduit Hole
BX or Romex Connector
Burner Box
Internal Wire Bundle
Green White Black
L1
L2
Gnd.
Connect wires together with
suitable approved wire connections.
Green to Gnd.
White to L2
Black to L1
Electrical Cord or
Flexible Conduit