background image

 

 

Please read this user manual carefully before using the device  
and keep it for future reference.

 

Following the manual's recommendations guarantees long-lasting and 
failure-free exploitation of the device

.

 

IT IS FORBIDDEN

 

 

1. Make repairs on your own and fail to comply with the rules contained in 
this manual regarding the connection and operation of the device;  
2. Store substances that may explode in the device, such as aerosols 
filled with combustible propellants; 
3. Place the device in the sun; 
4. Covering the inlet and outlet of air from the aggregate; 

5. Switching the device on to the mains without a properly 
functioning protective circuit system;

 

6. Use of extension cords and dividers to connect power. 
7. Use devices/objects that could cause an electric spark inside 
the device and in the aggregate chamber. 

WARNING! 

 

1. Incorrect connecting of the device to the mains may result in an 
electric shock.

 

2. In the event of sparks or breakdowns, immediately disconnect the 
device from the power supply by pulling the plug from the socket and 
calling an authorized service technician.

 

3. It is necessary to protect the wiring system and control system 
against water and mechanical damage. 
4. When servicing and replacing parts, the device must be 
disconnected from the power supply

 

 

CAUTION!

 

 

1. Before cleaning the condenser – 

switch the device off! 

2. When cleaning the condenser, do not use tools/objects that could 
cause an electric spark. 
3. Water condensation on glass panes and sheets at high relative 
humidity (over 60%) is a natural phenomenon. Long-term and frequent 
occurrence of dewing indicates inadequate ambient conditions and is 
not a basis for calling the service!

 

4. Take care when removing the glass panes. 
Breaking the glass panes can cause injury! 

 

 

i

The device is not intended for household use.

 

The device is not intended for outdoor use.

 

 

!

 

!

 

Summary of Contents for L-WB1

Page 1: ...1 TRANSLATED FROM ORIGINAL USER MANUAL MODULAR REFRIGERATED ISLAND L WB1 03 2021 EN...

Page 2: ...Product characteristics 5 3 Cooling system diagram 5 4 Wiring system 5 5 Wiring system diagram 6 6 Drawings 7 7 Positioning start up and operation 9 8 Maintenance 9 9 Transport and equipment 10 10 Tem...

Page 3: ...NG 1 Incorrect connecting of the device to the mains may result in an electric shock 2 In the event of sparks or breakdowns immediately disconnect the device from the power supply by pulling the plug...

Page 4: ...ated counter WB1 device model 141 127 device dimensions see table p 2 Important information on the rating label of each device In the case of contact with the service department prepare the following...

Page 5: ...ice 4 The device should be connected to a separate properly made electrical circuit protected by a fuse no greater than 10 A with a B characteristic ended with a socket with a protective pin 5 The dev...

Page 6: ...DIAGRAM SPR compressor MS condenser fan MN evaporator fan REG electronic temperature regulator CRT electronic temperature regulator sensor CKO defrost ending sensor WA aggregate switch PE protective c...

Page 7: ...7 Pic 1 6 DRAWINGS Pic 2 aggregate switch condenser evaporator compressor defrost water collection container fan loading limit air jet direction protective bumper power socket...

Page 8: ...8 Pic 3 exposure angle adjustment screw exposure angle adjustment screw...

Page 9: ...INTENANCE After disconnecting the device from power supply the general maintenance should be done by the user as follows 1 washing with water of the temperature not more than 40 C with addition of nat...

Page 10: ...flashes when the compressor s start up is delayed because of protective procedure It flashes in the cycle two flashes break when there is continuous operation mode activated 2 FAN The symbol is visibl...

Page 11: ...ng power supply of the controller on will cause return to the parameters fabric settings there will be shown CF symbol on the display In the parameters setting mode its pressing changes the informatio...

Page 12: ...parameter setting increase or decrease setting value by means of the UP and DOWN switches press the SET switch to temporarily save the entered new value it will cause as well return to the parameters...

Page 13: ...ended after exceeding the maximum duration rather than when reaching the end defrost set point The message disappears when the next defrost ends correctly EF displayed during operation or on power up...

Page 14: ...bove the storage temperature Too high ambient temperature hot air coming out of the aggregate chamber loud operation of the aggregate characteristic clicking coming out of the aggregate chamber every...

Page 15: ...ellants 3 The device is using natural and ecological refrigerant R 290 propane Warning In case of damage of the cooling system the refrigerator should be immediately disconnected from the mains any op...

Page 16: ...eramiczna Street BDO 000009031 tel 48 81 718 46 50 51 e mail rapa rapa lublin pl www rapapoland com The package should be removed according to the regulations of environmental protection The warranty...

Reviews:

Related manuals for L-WB1