11. INTERFERENCES 

 
 
The most often occurring interferences of the device operation: 

 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 

Reasons

 

Symptoms

 

Solution

 

Contaminated 
condenser

 

 

Visible dust layer on the condenser fins,

 

 

hot air coming out of the aggregate chamber,

 

 

loud operation of the aggregate,

 

 

characteristic "clicking" coming out of the 
aggregate chamber every few minutes

 

Before cleaning of the condenser it is 
necessary to switch the device off. 
Impurities on the condenser should be 
removed by means of vacuum cleaner 
equipped with brush, gently along fins to 
not to bend the lamella.

 

Device loaded with 
warm products

 

 

hot air coming out of the aggregate chamber,

 

 

loud operation of the aggregate,

 

 

characteristic "clicking" coming out of the 
aggregate chamber every few minutes

 

Goods loaded in the device chamber should 
be initially cooled up to m4°C above 
the storage temperature .

 

Too high ambient 
temperature

 

 

hot air coming out of the aggregate chamber,

 

 

loud operation of the aggregate,

 

 

characteristic "clicking" coming out of the 
aggregate chamber every few minutes

 

Ambient temperature for proper operation of 
the device should not exceed respectively: for 
3rd climatic class +25°C.

 

Improper goods 
distribution in 
cooling chamber

 

 

goods distributed not in accordance with the 
description in the user manual

 

The goods should be placed as described in 

user manual

.

 

External source of 
heat causing the 
abnormal 
operation of the 
device

 

 

hot air coming out of the aggregate chamber,

 

 

loud operation of the aggregate,

 

 

characteristic "clicking" coming out of the 
aggregate chamber every few minutes

 

External source of heat might be any other 
device that emits heat such as gas burner, 
heater, other device equipped with a 
refrigerated aggregate etc. It is necessary to 
pay attention if above mentioned examples 
may have influence on the deterioration of 
device operation conditions.

 

Summary of Contents for L-WB1

Page 1: ...1 TRANSLATED FROM ORIGINAL USER MANUAL MODULAR REFRIGERATED ISLAND L WB1 03 2021 EN...

Page 2: ...Product characteristics 5 3 Cooling system diagram 5 4 Wiring system 5 5 Wiring system diagram 6 6 Drawings 7 7 Positioning start up and operation 9 8 Maintenance 9 9 Transport and equipment 10 10 Tem...

Page 3: ...NG 1 Incorrect connecting of the device to the mains may result in an electric shock 2 In the event of sparks or breakdowns immediately disconnect the device from the power supply by pulling the plug...

Page 4: ...ated counter WB1 device model 141 127 device dimensions see table p 2 Important information on the rating label of each device In the case of contact with the service department prepare the following...

Page 5: ...ice 4 The device should be connected to a separate properly made electrical circuit protected by a fuse no greater than 10 A with a B characteristic ended with a socket with a protective pin 5 The dev...

Page 6: ...DIAGRAM SPR compressor MS condenser fan MN evaporator fan REG electronic temperature regulator CRT electronic temperature regulator sensor CKO defrost ending sensor WA aggregate switch PE protective c...

Page 7: ...7 Pic 1 6 DRAWINGS Pic 2 aggregate switch condenser evaporator compressor defrost water collection container fan loading limit air jet direction protective bumper power socket...

Page 8: ...8 Pic 3 exposure angle adjustment screw exposure angle adjustment screw...

Page 9: ...INTENANCE After disconnecting the device from power supply the general maintenance should be done by the user as follows 1 washing with water of the temperature not more than 40 C with addition of nat...

Page 10: ...flashes when the compressor s start up is delayed because of protective procedure It flashes in the cycle two flashes break when there is continuous operation mode activated 2 FAN The symbol is visibl...

Page 11: ...ng power supply of the controller on will cause return to the parameters fabric settings there will be shown CF symbol on the display In the parameters setting mode its pressing changes the informatio...

Page 12: ...parameter setting increase or decrease setting value by means of the UP and DOWN switches press the SET switch to temporarily save the entered new value it will cause as well return to the parameters...

Page 13: ...ended after exceeding the maximum duration rather than when reaching the end defrost set point The message disappears when the next defrost ends correctly EF displayed during operation or on power up...

Page 14: ...bove the storage temperature Too high ambient temperature hot air coming out of the aggregate chamber loud operation of the aggregate characteristic clicking coming out of the aggregate chamber every...

Page 15: ...ellants 3 The device is using natural and ecological refrigerant R 290 propane Warning In case of damage of the cooling system the refrigerator should be immediately disconnected from the mains any op...

Page 16: ...eramiczna Street BDO 000009031 tel 48 81 718 46 50 51 e mail rapa rapa lublin pl www rapapoland com The package should be removed according to the regulations of environmental protection The warranty...

Reviews:

Related manuals for L-WB1