11 

 

 

SWITCHES DESCRIPTION

 

Information: Short pressing of any of the switches causes appearance of 
message related to the currently active function. 

 

7. UP / ON OFF

 

During normal operation of the controller; pressed for longer than 3 sec. will cause 
change of controller ON/OFF operation state, pressed along with the “DOWN” 
switch at the same time for longer than 3 sec. will cause activation or deactivation 
of continuous operation function (after pressing there will be shown on the display 
“CC” symbol). In the parameters setting mode: enable going to the next 
parameters settings. During setting parameter values: it causes parameter value 
increase. 

 

8. SET / MUTE

 

Pressed during normal controller operation switches the alarm sound signal off; 
pressed for longer than 3 sec. shows setting point; pressed along with the 
“DOWN” switch at the same time while switching power supply of the controller on 
will cause return to the parameters fabric settings (there will be shown “CF” 
symbol on the display). In the parameters setting mode: its pressing changes the 
information shown on the display: parameter name/parameter value, pressed for 
longer than 3 sec. will cause saving of the set parameters. During setting 
parameter values: pressed it will cause saving of the entered parameter value. 

 

9. DOWN / DEFROST

 

During normal operation of the controller; pressed for longer than 3 sec. will cause 
switching on/off of the manual defrost mode. In the parameters setting mode: it 
allows to go to previous parameter setting. During setting parameter values: it 
decreases setting value. 

 

 

 

Set point setting (desired temperature value)

 

To view and modify the set point:

 

 

press the “SET” switch for 1 sec. – the set value will start flashing; 

 

increase or decrease the value using the “UP” or “DOWN” switches; 

 

press the “SET” switch to confirm the new value 
 

If the “SET” switch is not pressed for 60 sec., then the controller returns to 
previous settings

 

Summary of Contents for L-WB1

Page 1: ...1 TRANSLATED FROM ORIGINAL USER MANUAL MODULAR REFRIGERATED ISLAND L WB1 03 2021 EN...

Page 2: ...Product characteristics 5 3 Cooling system diagram 5 4 Wiring system 5 5 Wiring system diagram 6 6 Drawings 7 7 Positioning start up and operation 9 8 Maintenance 9 9 Transport and equipment 10 10 Tem...

Page 3: ...NG 1 Incorrect connecting of the device to the mains may result in an electric shock 2 In the event of sparks or breakdowns immediately disconnect the device from the power supply by pulling the plug...

Page 4: ...ated counter WB1 device model 141 127 device dimensions see table p 2 Important information on the rating label of each device In the case of contact with the service department prepare the following...

Page 5: ...ice 4 The device should be connected to a separate properly made electrical circuit protected by a fuse no greater than 10 A with a B characteristic ended with a socket with a protective pin 5 The dev...

Page 6: ...DIAGRAM SPR compressor MS condenser fan MN evaporator fan REG electronic temperature regulator CRT electronic temperature regulator sensor CKO defrost ending sensor WA aggregate switch PE protective c...

Page 7: ...7 Pic 1 6 DRAWINGS Pic 2 aggregate switch condenser evaporator compressor defrost water collection container fan loading limit air jet direction protective bumper power socket...

Page 8: ...8 Pic 3 exposure angle adjustment screw exposure angle adjustment screw...

Page 9: ...INTENANCE After disconnecting the device from power supply the general maintenance should be done by the user as follows 1 washing with water of the temperature not more than 40 C with addition of nat...

Page 10: ...flashes when the compressor s start up is delayed because of protective procedure It flashes in the cycle two flashes break when there is continuous operation mode activated 2 FAN The symbol is visibl...

Page 11: ...ng power supply of the controller on will cause return to the parameters fabric settings there will be shown CF symbol on the display In the parameters setting mode its pressing changes the informatio...

Page 12: ...parameter setting increase or decrease setting value by means of the UP and DOWN switches press the SET switch to temporarily save the entered new value it will cause as well return to the parameters...

Page 13: ...ended after exceeding the maximum duration rather than when reaching the end defrost set point The message disappears when the next defrost ends correctly EF displayed during operation or on power up...

Page 14: ...bove the storage temperature Too high ambient temperature hot air coming out of the aggregate chamber loud operation of the aggregate characteristic clicking coming out of the aggregate chamber every...

Page 15: ...ellants 3 The device is using natural and ecological refrigerant R 290 propane Warning In case of damage of the cooling system the refrigerator should be immediately disconnected from the mains any op...

Page 16: ...eramiczna Street BDO 000009031 tel 48 81 718 46 50 51 e mail rapa rapa lublin pl www rapapoland com The package should be removed according to the regulations of environmental protection The warranty...

Reviews: