LN-9259-07.1
1. Ensure that ground connections, cart ground,
and applicator ground are made to a true earth
ground.
OPERATION
W A R N I N G
> If true earth ground is not made, injury
to personnel or serious damage may occur
to the equipment.
> Ensure ALL items in the test area are
grounded. Ensure there are NO open
containers of flammable materials in the
test area.
> NEVER use solvent as a test fluid for this
device!
> Using any material OTHER than distilled
water or de-ionized water may cause fire
during the test. Use only distilled water or
de-ionized to test the applicator.
W A R N I N G
N O T E
> When opening dump valve for any test,
hold tubing securely by hand or clamp to
prevent whipping.
RMA TEST PROCEDURE
Setup
2. Provide air filtration to the manifold that has
the capability of passing 30 SCFM with particulate
removal of .3 to .6 micron particle size (bearing
air filtration is provided with the stand).
3. Provide a minimum 3/4-inch ID air line to the
filter at the manifold inlet. A minimum of 100 psig
pressure is required at the manifold inlet.
4. Install water supply line and air pressure line
to the pressure pot.
5. Fill the pressure pot liner with approximately
one (1) gallon of either de-ionized or distilled
water.
6. Plug the unit into a suitable 110/120V outlet.
INITIAL TEST SETTINGS
1. High voltage is off unless instructed to turn on.
Main power off.
Test Stations - Operation
9
N O T E
> Refer to the applicator service manual
for all parts and part number identifications.