background image

LN-9214-00.2

Digital Node Adapter - Installation

INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION

TION

TION

TION

TION

CONNECTIONS AND

CONNECTIONS AND

CONNECTIONS AND

CONNECTIONS AND

CONNECTIONS AND

CONFIGURA

CONFIGURA

CONFIGURA

CONFIGURA

CONFIGURATIONS

TIONS

TIONS

TIONS

TIONS

Input Power

Input Power

Input Power

Input Power

Input Power

Required input power is regulated 24 VDC
which is supplied by the mother board of the
rack which contains the Node Adapter.  An on
board dc-dc converter makes 5 VDC for the
modules logic level circuits.  In the 74847-00
Mother Board, connect the 24 VDC supply to
TB1-4 (+) and TB1-3 (-).

Remote I/O

Remote I/O

Remote I/O

Remote I/O

Remote I/O

The connection of the Allen-Bradley Remote I/O
(RIO) is made to the Digital/Analog Interface (DAIF)
Board.  This is plugged into the Node Adapter
connector at the rear

rear

rear

rear

rear of the mother board.  The

RIO cable wires are connected to J1 on the DAIF
as shown in Figure 1.  The RIO cable may be
“daisy-chained” from one node to another per
Allen-Bradley installation specifications.  Where a
termination resistor is specified, usually the last
termination point in a chain, the resistor R1 on the
DAIF board may be connected by placing switch
SW1 to the “TERM” position.  This connects the 82
Ohm resistor across blue and clear, appropriate
for 230 k baud rate.  If the RIO is configured for
another baud rate, place SW1 in the “OPEN”
position, and connect the appropriate resistor
directly across J1 “BLU” and “CLR”.

DAIF Board Jumpers

DAIF Board Jumpers

DAIF Board Jumpers

DAIF Board Jumpers

DAIF Board Jumpers

The DAIF board is used with the Digital Node
Adapter.  It is configured for each application by
positioning jumpers E1 and E2.  Figure 2b
shows the correct jumper position for Digital
Node Adapter communication to the FloTronics
Atomizer Fiber Optic Speed Control Module.
Figure 2a shows the correct jumper position for
Digital Node Adapter communication to the
FloTronics Digital Air Control Module.

Connection to Slave Half-Rack

Connection to Slave Half-Rack

Connection to Slave Half-Rack

Connection to Slave Half-Rack

Connection to Slave Half-Rack

The Digital Node Adapter communicates to five
FloTronics Digital or Atomizer Modules via its own
mother board.  It can communicate to an additional
mother board with modules (slave half-rack) by
connecting the Digital/Analog cable (DACAB) from
J2 on the DAIF board to J1 on the slave half-rack
mother board.

Node Adapter

Node Adapter

Node Adapter

Node Adapter

Node Adapter
Addressing / Configuration

Addressing / Configuration

Addressing / Configuration

Addressing / Configuration

Addressing / Configuration

The Digital Node Adapter must be set for the
appropriate RIO address.  The rack address
and starting quarter are set by switch SW2 as
shown in Figure 3.  The Operating Mode, Last
State, Baud Rate and Rack Size are set by
positions 1-5 on switch SW1 as shown in Figure
3.

Figure 1:  Remote I/O Connections

Figure 1:  Remote I/O Connections

Figure 1:  Remote I/O Connections

Figure 1:  Remote I/O Connections

Figure 1:  Remote I/O Connections

RIO Wire

RIO Wire

RIO Wire

RIO Wire

RIO Wire

Blue

Bare

Clear

DAIF J1 Position

DAIF J1 Position

DAIF J1 Position

DAIF J1 Position

DAIF J1 Position

  BLU

SHLD

CLR

6

6

6

6

6

Summary of Contents for 75584

Page 1: ...SAFETY PRECAUTIONS carefully read SAFETY PRECAUTIONS carefully read SAFETY PRECAUTIONS carefully read SAFETY PRECAUTIONS carefully read SAFETY PRECAUTIONS starting on page 1 and all instructions in s...

Page 2: ...from revision LN 9214 00 1 LN 9214 00 1 LN 9214 00 1 LN 9214 00 1 LN 9214 00 1 to revision LN 9214 00 2 LN 9214 00 2 LN 9214 00 2 LN 9214 00 2 LN 9214 00 2 Reasons for this change are noted under Manu...

Page 3: ...ZER MAX MODE BTW ATOMIZER MIN MODE BTW ATOMIZER MIN MODE BTR 1 3 1 3 1 3 1 3 1 3 4 5 4 5 4 5 4 5 4 5 6 8 6 8 6 8 6 8 6 8 9 14 9 14 9 14 9 14 9 14 1 2 4 4 4 5 6 7 8 9 10 11 12 13 14 14 Digital Node Ada...

Page 4: ......

Page 5: ...ce A NOTE is information relevant to the proce A NOTE is information relevant to the proce A NOTE is information relevant to the proce A NOTE is information relevant to the proce dure in progress dure...

Page 6: ...isabled during op eration Frequent power supply shutdown indicates a problem in the system requiring correction Fire extinguishing equipment must be present in the spray area and tested periodically S...

Page 7: ...quire high voltage to be on but only as instructed Production should never be done with the safety circuits disabled Before turning the high voltage on make sure no objects are within the sparking dis...

Page 8: ...cifically to communicate with the proprietary protocol of the RIO serial link The central component of this block is an application specific IC ASIC which is capable of formatting the RIO information...

Page 9: ...nd slot 10 Digital Modules may be replaced by A10204 01 Discrete Modules when 74787 00S mother board is used Min Mode Min Mode Min Mode Min Mode Min Mode DGNA communicates to up to five Digital Module...

Page 10: ...Jumpers DAIF Board Jumpers DAIF Board Jumpers DAIF Board Jumpers The DAIF board is used with the Digital Node Adapter It is configured for each application by positioning jumpers E1 and E2 Figure 2b s...

Page 11: ...E1 E2 Jumpers For Use With 75119 02 Digital Modules Figure 2a E1 E2 Jumpers For Use With 75119 02 Digital Modules Figure 2b E1 E2 Jumpers For Use With 74944 100 Atomizer Modules Figure 2b E1 E2 Jumper...

Page 12: ...al Node Adapter Module Switch Settings Figure 3 Digital Node Adapter Module Switch Settings Figure 3 Digital Node Adapter Module Switch Settings Figure 3 Digital Node Adapter Module Switch Settings Fi...

Page 13: ...onfigured for logical rack of PLC space The DGNA is located in slot 0 if Digital Modules are located in slots 1 5 or slot 6 if Digital Modules are located in slots 7 11 of a 74749 rack A DAIF board is...

Page 14: ...put Channel 5 Digital Output Channel 6 Digital Output Channel 7 Digital Output Channel 8 Digital Output Channel 1 Digital Output Channel 2 Digital Output Channel 3 Digital Output Channel 4 Digital Out...

Page 15: ...nel 3 Digital Output Channel 4 Digital Output Channel 5 Digital Output Channel 6 Digital Output Channel 7 Digital Output Channel 8 Digital Output Channel 1 Digital Output Channel 2 Digital Output Chan...

Page 16: ...0 255 equals 0 100 psi Bell speed 0 70 equals 0 70 000 rpm Module status word Drive pressure 0 255 equals 0 100 psi Bell speed 0 70 equals 0 70 000 rpm Module status word Drive pressure 0 255 equals 0...

Page 17: ...Atomizer 4 Atomizer 5 Atomizer 6 Atomizer 7 Atomizer 8 Atomizer 9 Atomizer 10 Bell speed command 0 70 equals 0 70 000 rpm Bell speed command 0 70 equals 0 70 000 rpm Bell speed command 0 70 equals 0...

Page 18: ...atus word Drive pressure 0 255 equals 0 100 psi Bell speed 0 70 equals 0 70 000 rpm Module status word Drive pressure 0 255 equals 0 100 psi Bell speed 0 70 equals 0 70 000 rpm A A A A AT T T T TOMIZE...

Page 19: ...ption Possible Cause Possible Cause Possible Cause Possible Cause Possible Cause ON OFF BLINK OFF OFF Normal operation Adapternotcommunicating Adapter not controlling I O Node Adapter processor not ac...

Page 20: ...umbers Figure 11 Part Numbers Figure 11 Part Numbers Figure 11 Part Numbers Digital Node Adapter Digital AnalogInterface Board Digital AnalogCable 01and 02arefunctionallyidentical 02islabeledwith ITW...

Page 21: ...LN 9214 00 2 Digital Node Adapter Parts Identification 17 17 17 17 17 NOTES NOTES NOTES NOTES NOTES...

Page 22: ...RTS THAT HAVE FAILED BE PLACE PARTS THAT HAVE FAILED BE PLACE PARTS THAT HAVE FAILED BE CAUSE OF FAULTY WORKMANSHIP CAUSE OF FAULTY WORKMANSHIP CAUSE OF FAULTY WORKMANSHIP CAUSE OF FAULTY WORKMANSHIP...

Page 23: ...K SC 100 DIBK Amyl Alcohol Butyl Cellosolve SC 150 Chlorinated Solvents Aliphatic Hydrocarbons Ketones Esters Aromatic Hydrocarbons Esters Ketones Esters Alcohols Ketones Alcohols Esters Aromatic Hydr...

Page 24: ...n 2 Zahn 2 Zahn 3 Zahn 3 Zahn 3 Zahn 3 Zahn 3 Zahn 4 Zahn 4 Zahn 4 Zahn 4 Zahn 4 Zahn 5 Zahn 5 Zahn 5 Zahn 5 Zahn 5 Sears Sears Sears Sears Sears Craftsman Cup Craftsman Cup Craftsman Cup Craftsman Cu...

Page 25: ...ithographic Lithographic Krebs Unit Krebs Unit Krebs Unit Krebs Unit Krebs Unit K U K U K U K U K U Saybolt Saybolt Saybolt Saybolt Saybolt Universal SSU Universal SSU Universal SSU Universal SSU Univ...

Page 26: ...3 fl oz 102 gal 13 1 fl oz 010 gal 1 2 fl oz 022 gal 2 8 fl oz 038 gal 4 9 fl oz 060 gal 7 6 fl oz 086 gal 11 0 fl oz 153 gal 19 6 fl oz 016 gal 2 0 fl oz 036 gal 4 6 fl oz 064 gal 8 2 fl oz 100 gal...

Page 27: ...00 1 LN 9214 00 1 LN 9214 00 1 LN 9214 00 1 Digital Node Adapter to make the following changes 1 New drawing on front cover 2 Replace reference to NFPA 33 1995 edition with 2000 edition 3 Updated War...

Page 28: ...hone 800 626 3565 Fax 419 470 2040 Industrial Systems Telephone 800 233 3366 Fax 419 470 2071 Ransburg Guns Telephone 800 233 3366 Fax 419 470 2071 T T T T Technical Support Representative will direct...

Reviews: