Trouble Shooting
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The burner
does not light
up.
The connection between the
regulator and LP Tank are not
in good condition.
Check and make sure the
regulator coupling nut is
tightened to the LP tank
valve.
The LP tank valve and
regulator control valve do not
open.
The regulator control valve
and LP tank valve is open
during normal operation. The
regulator control valve is
opened in clockwise direction
and the LP tank valve is
opened in counter-clockwise
direction.
The LP tank is empty.
Check and make sure the LP
tank is filled with fuel.
Push button of safety valve
was not pushed down.
Press and fully hold down
push button of safety valve
after the lighted match is
placed on the burner.
The burner
does not stay lit.
The push button on safety
valve was not fully pushed
down for at least 10 seconds.
Fully hold down the push
button on safety valve at least
10 seconds and then release.
Timer is not activated.
Fully turn the timer control
knob clockwise.
The thermocouple is not in
direct flame path of burner.
Ensure the thermocouple is
assembled in right position
and the nut is tightened on
the thermocouple. (See
Assembly Instruction - step 2
for detail) Make sure the
flame has full contact with the
thermocouple.
High wind condition.
If wind blows out flame, gas
supply will be cut off. Move
out of wind and restart.
Timer has completed its cycle.
Each cycle of timer is 15
minutes, after 15 minutes, the
burner will go off
automatically. Please re-set
the timer.