9 of 43 20111206-Ver7
LIGHTING THE SIDE BURNER (Side burner):
DANGER
Never close the SIDE BURNER LID during operation
1. Read all instructions before lighting.
2. Open lid during lighting.
3. Push and turn main burner knob slowly to HI. The
side burner should light immediately.
4. Once burner is lit, continue to push and hold
control knob for 45 seconds.
5. If ignition does not occur in 5 seconds, turn the
knob off, wait 5 minutes, then repeat the lighting
procedure or light by match.
6. To turn burners off, turn the control knob clockwise until it locks in the OFF
position. Turn gas supply to OFF.
MATCH LIGHTING THE MAIN BURNERS:
1. Turn
OFF
all burner valves.
2. Make sure the lid is open.
3. Place a lighted match between the coils on the
extension rod and hold next to the burner.
4. Turn the control knob(s) to the “HI/Light” position.
Burner should light immediately.
5. For infra-red side burner, once the burner is lit
continue to push and hold control knob for 45
seconds.
6. If the burner does not light in 4 seconds turn the
knob off, wait 5 minutes and repeat above
procedures.
MATCH LIGHTING THE SIDE BURNER:
7. Turn
OFF
all burner valves.
8. Make sure the lid is open.
9. Strike and carefully place a long match 1/2” (1 to 2
cm) from the side burner
10. Turn the control knob to the “HI/Light” position.
Burner should light immediately.
11. Once the burner is lit continue to push and hold
control knob for 45 seconds.
12.
If the burner does not light in 4 seconds turn the knob
off, wait 5 minutes and repeat above procedures.
Lighting Hole
Lighting Rod
Match