Enter Device Manager in control panel properties and remember the name of COM-port, used by the
table. After starting ScanCenter (look below) in scanner configuration settings (
Adjustment – Configuration –
Rotary table
) write the port number in the field
Device number.
Choose the model of the table -
TS-12 (
since 01.2016) or
Default
If the table wasn`t successfully connected, during scanning the error will occur. Check the connection of
the turn table, driver setup and correctness of COM-port number in
scanner configuration settings.
For checking efficiency of the table, turn it for a little angle. On
the menu choose
Adjustment→
Table calibration.
Enter the angle
number and press
Turn
. The table must rotate clockwise, viewed
from above. If the table rotates in another direction, change the
parameter -
Change the direction
in configuration settings.