background image

 

 

 

 

EN 

9

 

USE

 

Control panel 

 
 
 
 
 
 

Key Function 

Display 

Upper panel closed: when pressed for about one sec-
ond it opens the upper panel. It switches the motor on 
at the latest  selected speed. 
Upper panel open: when shortly pressed it switches 
the motor on/off. 

Indicates the selected speed. 

Decreases the suction speed. 

Number of lit LEDS decreases. 

Increases the suction speed. 

Number of lit LEDS increases. 

Functioning only when the upper panel is open. This 
speed has been timed at 10 minutes. After that time 
the system activates automatically the latest selected 
speed. The function is suitable for cooking conditions 
when vapours and smells are of the utmost emission. 

flashes

 

and

 

all the LEDS on the display 

are lit.

 

By pressing the key the function is deacti-
vated. 

Functioning only when the upper panel is open. By 
pressing this key it is possible to set up the motor to a 
suction speed at 100 m

3

/h .  

24

–symbol appears and the LEDS on the 

display go off cyclically, one by one.  
By pressing the key the function is deacti-
vated. 

Functioning only when the motor is on. By pressing 
this key it is possible to set the delayed shutdown of 
the motor and the lighting to 30 minutes.  

A flashing 

clock

 symbol appears.  

By pressing the key the function is deacti-
vated. 

By pressing this key for about 2 seconds it is possible 
to 

reset 

the filter saturation alarm.  

drop

 symbol indicates that the metal 

grease filters saturation alarm has been 
activated, and the filters need to be 
washed. The alarm is triggered after 100 
working hours.  

C

 indicates that the charcoal filter satura-

tion alarm has been activated, and the filter 
has to be replaced. The alarm s triggered 
after 200 working hours.  

By pressing this key the intensity of the lighting sys-
tem can be modified up to five levels. 

 

Upper panel closed: when pressed for about 1 second 
it opens the upper panel and sets the lights at the 
maximum intensity. 
Upper panel open: when shortly pressed it switches 
the lights on/off. 

 

Upper panel closed: when pressed for about one sec-
ond it opens the upper panel and switches the motor 
on at the third speed and the lights at the maximum 
intensity. 
Upper panel open: when pressed for about 1 second it 
switches off motor and lights resetting every activated 
function, and closes the upper panel. 

 

 
Keyboard lock: it is possible to jam the keyboard when, for example, cleaning the glass. The 
motor and lights are switched off, and upper panel can be open or closed. 
By pressing the 

F

-key (Delay) for about 5 seconds the keyboard block can be activated or de-

activated. This function is confirmed by a Beep and by moving motor LEDS on display. 

 

B

A

D

C

E

G

F

I

H

L

Summary of Contents for GLX490 RM

Page 1: ...GLX490 RM GALAXY HOOD GLASS Instructions Manual www rangemaster co uk...

Page 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 11...

Page 3: ...is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overhea...

Page 4: ...EN 4 4 CHARACTERISTICS Dimensions...

Page 5: ...1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 16 1 Cover for recycling version Ref Q ty Installation components 7 2 1 2 Fixing brackets for upper chimney 7 3 1 Air Outlet Connection...

Page 6: ...key for one second see Part USE Disconnect the hood from the mains supply Attention the upper panel stops if any barrier occurs in its way during the panel opening or closing To open the panel it is...

Page 7: ...nto the Support bracket 7 3 and fix it with a screw Make sure that the outlet of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Connect the air outlet conne...

Page 8: ...kets using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and ho...

Page 9: ...the key the function is deacti vated G By pressing this key for about 2 seconds it is possible to reset the filter saturation alarm A drop symbol indicates that the metal grease filters saturation al...

Page 10: ...pper panel closed opens the upper panel switches on the motor at the latest se lected speed Upper panel open switches the motor on off When pressed for about 2 Seconds upper panel closed opens the upp...

Page 11: ...sing the A key for 1 second see Part USE Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of the filters has t...

Page 12: ...sh Within 3 seconds press the D key to activate deactivate charcoal filter saturation alarm C symbol lit charcoal filter saturation alarm ACTIVATED C symbol unlit charcoal filter saturation alarm DEAC...

Page 13: ...ry to enable the manual opening of the panel After having completely opened the panel remove the metal grease filters as explained in the part concern ing the filter cleaning The fuser is placed up on...

Page 14: ......

Page 15: ......

Page 16: ...436004217_ver1 AGA RANGEMASTER LTD...

Reviews: