background image

 

 

 

 

EN 

7

 

RECYCLING VERSION AIR OUTLET 

To install the hood in recycling version, the optional charcoal 
filter kit must be purchased. 
 
•  Remove the chimney angle bracket. 
•  Screw the filter cover onto the air outlet, using four screws 

12c

 

(2.9 x 12.5). 

•  Fix the air outlet grid 

8

 on the recirculation air outlet using the 

2 screws 

12d

 (2,9 x 9,5) provided. 

 

16

12c

12d

8

RECIRCULATION VERSION AIR OUTLET 

•  Insert the connection extension pieces laterally 

14.1

 in connec-

tion 

15.

 

•  Insert the Connector 

15

 into the Support bracket 

7.3

 and fix it 

with a screw. 

•  Make sure that the outlet of the extension pieces 

14.1

 is hori-

zontally and vertically aligned with the chimney outlets.  

•  Connect the air outlet connection 

15

 to the hood body outlet 

using either a flexible or rigid pipe   ø 150 mm, the choice of 
which is left to the installer. 

•   Ensure that the activated charcoal filters have been inserted. 

 

ø 150

15

14.1

7.3

ELECTRICAL CONNECTION 

•  Connect the hood to the mains supply. 
•  Open the upper panel by pressing the 

A

-key (See Part “USE” ) 

for at least 2 seconds. 

•  Remove the metal filters (See Part “MAINTENANCE”) and 

make sure that the connector piece of the supply cable is cor-
rectly inside the hood socket. 

 

Summary of Contents for GLX490 RM

Page 1: ...GLX490 RM GALAXY HOOD GLASS Instructions Manual www rangemaster co uk...

Page 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 11...

Page 3: ...is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overhea...

Page 4: ...EN 4 4 CHARACTERISTICS Dimensions...

Page 5: ...1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 16 1 Cover for recycling version Ref Q ty Installation components 7 2 1 2 Fixing brackets for upper chimney 7 3 1 Air Outlet Connection...

Page 6: ...key for one second see Part USE Disconnect the hood from the mains supply Attention the upper panel stops if any barrier occurs in its way during the panel opening or closing To open the panel it is...

Page 7: ...nto the Support bracket 7 3 and fix it with a screw Make sure that the outlet of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Connect the air outlet conne...

Page 8: ...kets using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and ho...

Page 9: ...the key the function is deacti vated G By pressing this key for about 2 seconds it is possible to reset the filter saturation alarm A drop symbol indicates that the metal grease filters saturation al...

Page 10: ...pper panel closed opens the upper panel switches on the motor at the latest se lected speed Upper panel open switches the motor on off When pressed for about 2 Seconds upper panel closed opens the upp...

Page 11: ...sing the A key for 1 second see Part USE Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of the filters has t...

Page 12: ...sh Within 3 seconds press the D key to activate deactivate charcoal filter saturation alarm C symbol lit charcoal filter saturation alarm ACTIVATED C symbol unlit charcoal filter saturation alarm DEAC...

Page 13: ...ry to enable the manual opening of the panel After having completely opened the panel remove the metal grease filters as explained in the part concern ing the filter cleaning The fuser is placed up on...

Page 14: ......

Page 15: ......

Page 16: ...436004217_ver1 AGA RANGEMASTER LTD...

Reviews: