Install the tap:

Install the tap:

Install the tap:

Install the tap:    

    

This diagram shows the view of 
the base of the tap (A1) with 
the 98°C water handle to the 
left of the body. 

 

YOU MUST 

CAREFULLY 
ACKNOWLEDGE 
THE INLETS AND 
OUTLETS AS 
SHOWN

 

 

 

 

1.

 

Screw the fixing stud (A8) into base of tap (A1) as shown on the diagram. 

 

2.

 

Place the base plinth (A2) and base plinth seal (A3) onto the base of the tap (A1). 

 

3.

 

Hand tighten the domestic hot in flexible hose (E1) as shown in the diagram. 

 

4.

 

Hand tighten the domestic cold in flexible hose (F1) as shown in the diagram. 

 

5.

 

Hand tighten the filtered cold in flexible hose (C1) as shown in the diagram.

Hand tighten the filtered cold in flexible hose (C1) as shown in the diagram.

Hand tighten the filtered cold in flexible hose (C1) as shown in the diagram.

Hand tighten the filtered cold in flexible hose (C1) as shown in the diagram.    

⚠    

TAKE CARE NOT 

TAKE CARE NOT 

TAKE CARE NOT 

TAKE CARE NOT 

TO INVERT (C1) & (B1). 

TO INVERT (C1) & (B1). 

TO INVERT (C1) & (B1). 

TO INVERT (C1) & (B1). 
DOING SO WILL RESULT 

DOING SO WILL RESULT 

DOING SO WILL RESULT 

DOING SO WILL RESULT 
IN NO FILTERED WATER

IN NO FILTERED WATER

IN NO FILTERED WATER

IN NO FILTERED WATER

    

6.

 

Hand tighten the filtered cold out flexible hose (B1) as shown in the diagram. 

Hand tighten the filtered cold out flexible hose (B1) as shown in the diagram. 

Hand tighten the filtered cold out flexible hose (B1) as shown in the diagram. 

Hand tighten the filtered cold out flexible hose (B1) as shown in the diagram.     

 

7.

 

Hand tighten the 110° rated steaming hot flexible hose (D1) into the centre inlet as shown on the diagram. 

 

8.

 

Place the tap (A1-A3) centrally and straight to the tap hole, passing the fixing stud (A8), flexi hoses (B1, C1, 
D1, E1 & F1) through the tap hole. 

 

9.

 

Pass the lower gasket (A6) then the metal horseshoe (A7) over the fixing stud (A8).  Note: only if the tap is 
to be fitted to a stainless steel sink then the white triangular plate (A5) can be fitted where shown to 
improve the stability of the tap. 

 

10.

 

Using a 13mm box spanner or small adjustable spanner tighten fixing nut (A9) onto the fixing stud (A8). 

 

11.

 

Screw pushfit (B3) into brass adaptor (B2) and pushfit (C3) into brass adaptor (C2)    

⚠ 

We

We

We

We    recommend using PTFE tape (do not use sealing compound) on the thread of 

recommend using PTFE tape (do not use sealing compound) on the thread of 

recommend using PTFE tape (do not use sealing compound) on the thread of 

recommend using PTFE tape (do not use sealing compound) on the thread of the 

the 

the 

the pushfit

pushfit

pushfit

pushfit    fittings

fittings

fittings

fittings    

to make a good seal without applying excessive force (which may damage the plastic pushfit if 

to make a good seal without applying excessive force (which may damage the plastic pushfit if 

to make a good seal without applying excessive force (which may damage the plastic pushfit if 

to make a good seal without applying excessive force (which may damage the plastic pushfit if 
overtightened).

overtightened).

overtightened).

overtightened).    

 

12.

 

Screw pushfit (B3) and adaptor (B2) into the filtered cold out flexible hose (B1). 

 

13.

 

Screw pushfit (C3) and adaptor (C2) into the filtered cold in flexible hose (C1). 

 

14.

 

Connect the domestic hot water flexible hose (E1) to the hot water isolation valve (G1) using a section of 
15mm pipe (G4) and compression nuts (G3) and olives (G2). 

 

Summary of Contents for GEO Intense GEO4TIDCM

Page 1: ...e installation or use and retain for future reference You must install the tap and filter before the boiler We have a policy of continued product and quality development and improvement Accordingly we...

Page 2: ...BE MADE BY CHILDREN ALL WITH THE APPLIANCE CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN ALL WITH THE APPLIANCE CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN ALL WITH THE A...

Page 3: ...iled filtered water Fully push the left side handle lever down Fig 2 and then simultaneously turn the handle forwards Fig 3 the further forwards the lever is turned the greater the flow up to a maximu...

Page 4: ...E years from the date of purchase provided that our advice concerning care has been observed and no scouring agents have been used This is provided that the mixer has been used for normal domestic pur...

Page 5: ...elaws Where hot and cold water mix within the tap then suitable non return check valves should be installed to both the hot and cold supplies to prevent backflow a preinstalled non return valve on the...

Page 6: ...the existing supply pipework is required if this is the case do this now Shut off your water heating system and ensure that your mains stopcock is closed Open the lowest hot and cold taps in the house...

Page 7: ...hfit 1 C4 outside diameter plastic pipe 1 C5 Filter bracket 1 C6 Filter bracket screw 1 C7 Filter cartridge 1 C8 outside diameter plastic pipe 1 C9 BSPF x pushfit adaptor 1 D1 Steaming hot water from...

Page 8: ...nlet as shown on the diagram 8 Place the tap A1 A3 centrally and straight to the tap hole passing the fixing stud A8 flexi hoses B1 C1 D1 E1 F1 through the tap hole 9 Pass the lower gasket A6 then the...

Page 9: ...ive G6 and a section of 15mm pipe F5 18 Screw the BSP x pushfit C9 onto the three way valve G7 male output Install the Filter Install the Filter Install the Filter Install the Filter 1 Find a suitable...

Page 10: ...ket 6 Turn on the 98 C forwards handle fully keep the lever open until all air is expelled and cold filtered water exits the pipe B4 into the bowl flush a minimum of a further 2 litres of cold filtere...

Reviews: