Installation Preparation

Installation Preparation

Installation Preparation

Installation Preparation    

You must install the mixertap and filter before the boiler.

 

 

Before installing the new mixer it is essential that you thoroughly flush through the supply pipes

flush through the supply pipes

flush through the supply pipes

flush through the supply pipes in order 

to remove any remaining solder, swarf or impurities from your system. Failure to carry out this simple 
procedure could cause problems or damage to the workings of the mixertap or boiler. 

We recommend installing particle filters (not shown) and isolation valves (G1) to both the hot and cold 

feed pipes in an accessible position. This will help to prevent premature failure of the valves and ease any 
future maintenance. 

 Ensure you have suitable domestic hot and cold water pressure before installing this product (see 

technical data). 

 All parts should be removed from their packaging and inspected for any transport damage and 

completeness prior to installation. 

Loosely position the tap, pipes and other principal supply components to check if any alterations to the 

existing supply pipework is required, if this is the case do this now. 

 

Shut off your water heating system and ensure that your mains stopcock is closed. Open the lowest hot 

and cold taps in the house and allow the water to run until fully stopped. 

If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool, the tap hole area 
should be free from dirt and sealant.  

 
This mixertap requires a Ø35mm tap hole, as both 
handles rotate backwards and forwards you should 
allow for this distance “A

A

A

A” behind the tap when 

planning the sink and tap hole location as shown. 

 

This tap is designed to be installed in a 

This tap is designed to be installed in a 

This tap is designed to be installed in a 

This tap is designed to be installed in a worktop

worktop

worktop

worktop    

with a maximum thickness of 45

with a maximum thickness of 45

with a maximum thickness of 45

with a maximum thickness of 45mm.

mm.

mm.

mm.  

 

For this product “A” should be no less that 70mm 

For this product “A” should be no less that 70mm 

For this product “A” should be no less that 70mm 

For this product “A” should be no less that 70mm 

(Tap hole centre to tiled wall or backsplash face)

(Tap hole centre to tiled wall or backsplash face)

(Tap hole centre to tiled wall or backsplash face)

(Tap hole centre to tiled wall or backsplash face)

 

 

Summary of Contents for GEO Intense GEO4TIDCM

Page 1: ...e installation or use and retain for future reference You must install the tap and filter before the boiler We have a policy of continued product and quality development and improvement Accordingly we...

Page 2: ...BE MADE BY CHILDREN ALL WITH THE APPLIANCE CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN ALL WITH THE APPLIANCE CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN ALL WITH THE A...

Page 3: ...iled filtered water Fully push the left side handle lever down Fig 2 and then simultaneously turn the handle forwards Fig 3 the further forwards the lever is turned the greater the flow up to a maximu...

Page 4: ...E years from the date of purchase provided that our advice concerning care has been observed and no scouring agents have been used This is provided that the mixer has been used for normal domestic pur...

Page 5: ...elaws Where hot and cold water mix within the tap then suitable non return check valves should be installed to both the hot and cold supplies to prevent backflow a preinstalled non return valve on the...

Page 6: ...the existing supply pipework is required if this is the case do this now Shut off your water heating system and ensure that your mains stopcock is closed Open the lowest hot and cold taps in the house...

Page 7: ...hfit 1 C4 outside diameter plastic pipe 1 C5 Filter bracket 1 C6 Filter bracket screw 1 C7 Filter cartridge 1 C8 outside diameter plastic pipe 1 C9 BSPF x pushfit adaptor 1 D1 Steaming hot water from...

Page 8: ...nlet as shown on the diagram 8 Place the tap A1 A3 centrally and straight to the tap hole passing the fixing stud A8 flexi hoses B1 C1 D1 E1 F1 through the tap hole 9 Pass the lower gasket A6 then the...

Page 9: ...ive G6 and a section of 15mm pipe F5 18 Screw the BSP x pushfit C9 onto the three way valve G7 male output Install the Filter Install the Filter Install the Filter Install the Filter 1 Find a suitable...

Page 10: ...ket 6 Turn on the 98 C forwards handle fully keep the lever open until all air is expelled and cold filtered water exits the pipe B4 into the bowl flush a minimum of a further 2 litres of cold filtere...