![background image](http://html1.mh-extra.com/html/rands/m3sr-4100-series/m3sr-4100-series_operating-manual_3081105512.webp)
M3SR Series 4100
Starting ATU Learning for SECOM-H Hopset
4.176
Operating Manual 6175.4760.02 – 01
4.8.3.11
Starting ATU Learning for SECOM-H Hopset
By means of softkey 'ATU Learn' the operator can start ATU learning for a SECOM-H hopset.
This function is only available with a connected antenna tuning unit.
Softkey
Type
Description
Activate
Start the ATU tuning process in the selected
frequency range.
Starting ATU Learning
1.
Press 'ATU Learn' softkey to start the
learning process.
The ATU starts learning on the currently se-
lected SECOM-H hopset.
The tuning process can be aborted any
time by pressing the 'ESC/CLR' button.
During learning the following status is dis-
played:
If learning was successful, the following status
is displayed:
By using the 'ATU learn' function ATU settings
are stored in a selectable memory bank. In the
learning procedure all SECOM-H channels of
the hopset are set. In each case the antenna
tuning unit will start tuning anew.
If learning is aborted, the following status is
displayed:
Summary of Contents for M3SR 4100 Series
Page 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Page 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Page 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Page 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Page 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Page 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Page 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Page 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...