![R&S M3SR 4100 Series Operating Manual Download Page 107](http://html1.mh-extra.com/html/rands/m3sr-4100-series/m3sr-4100-series_operating-manual_3081105107.webp)
Operating Manual 6175.4760.02 – 01
2.37
M3SR Series 4100
Basic Configuration of the Radio
To change the IP settings of the radio using the upd32.exe proceed as follows:
1.
Connect radio backplane LAN connector and PC to LAN (see Figure 2.15).
2.
Press the Erase button at the radio front panel (make sure that radio is switched off be-
forehand).
3.
Switch the PC on and start the upd32.exe.
4.
Select 'LAN Settings via Ethernet' in Config menu of upd32.exe (see Figure 2.16).
5.
Switch the radio on (see sect. 2.6 Switching the Radio On).
6.
Wait until the MAC address of your radio has come up in upd32.exe dialog 'Select Tar-
gets for Ethernet communication' (see Figure 2.17).
7.
Select the radio MAC address of your radio in upd32.exe dialog 'Select Targets for Eth-
ernet communication' and select 'Ok' (see Figure 2.17).
8.
The upd32.exe dialog 'LAN settings' is coming up showing the current IP settings of your
radio (IP address, subnet mask, gateway and local IP address).
9.
Change the radio IP settings as required in the dialog 'LAN settings'.
10. Press 'OK' to load the settings to the radio.
11. After a moment a message box comes up with the option to continue and update the ra-
dio functional SW as well. Select 'No' to finish the update without updating the radio func-
tional SW (see Figure 2.19).
12. Switch the radio off to make the changes take effect. Switch the PC off.
After changing the radio IP settings (especially radio IP address) it is also required to
change the built-in control unit IP settings (especially radio IP address list, see
Figure 2.17). The local IP address is the IP address of the local (built-in) control unit.
The radio identifies the local control unit by its IP address (see also sect. 3.3 Control
and Monitoring of Radio and Control Unit).
Summary of Contents for M3SR 4100 Series
Page 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Page 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Page 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Page 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Page 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Page 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Page 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Page 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...