background image

Headphones

RS-232-C cable

AC power supply

AC supply connector
(country-specific)

VSWR Bridge and 

Power Divider ¸FSH-Z2

Power Sensor
¸FSH-Z1

Power sensor

connector on ¸FSH3

Optional accessories

Designation

Type

Order No.

Power Sensor, 10 MHz to 8 GHz

¸FSH-Z1

1155.4505.02

VSWR Bridge and Power Divider, 10 MHz to 3 GHz

 

(open, short, 50 

W

 load)

¸FSH-Z2

1145.5767.02

VSWR Bridge with DC Bias and Bypass Connector for the R&S®FSH, 10 MHz to 6 GHz (incl. 
calibration standards open, short, 50 

W

 load)

R&S®FSH-Z3

1300.7756.02

Directional Power Sensor, 25 MHz to 1 GHz

¸FSH-Z14

1120.6001.02

Power Sensor, 10 MHz to 18 GHz

¸FSH-Z18

1165.1909.02

Directional Power Sensor, 200 MHz to 4 GHz

¸FSH-Z44

1165.2305.02

Matching Pad 50/75 

W

, 0 Hz to 2700 MHz

¸RAZ

0358.5714.02

Spare RF Cable (1 m), connectors N male/N female for ¸FSH-B1

¸FSH-Z20

1145.5867.02

12 V Car Adapter

¸FSH-Z21

1300.7579.02

Serial/Parallel Converter

¸FSH-Z22

1145.5880.02

Carrying Bag

¸FSH-Z25

1145.5896.02

Transit Case

¸FSH-Z26

1300.7627.02

Combined Short/Open and 50 

W

 Load for VSWR and DTF calibration

¸FSH-Z29

1300.7504.02

Spare Short/Open Calibration Standard for ¸FSH-Z2 for VSWR calibration

¸FSH-Z30

1145.5773.02

Spare 50 

Load Standard for ¸FSH-Z2 for VSWR and DTF calibration

¸FSH-Z31

1145.5780.02

Spare Battery Pack

¸FSH-Z32

1145.5796.02

Spare AC Power Supply

¸FSH-Z33

1145.5809.02

Spare RS-232-C Optical Cable

¸FSH-Z34

1145.5815.02

Spare CD-ROM with Control Software ¸FSH View and documentation

¸FSH-Z35

1145.5821.02

Spare Headphones

¸FSH-Z36

1145.5838.02

Spare USB Optical Cable

¸FSH-Z37

1300.7733.02

Matching Pad 50/75 

W

, 0 Hz to 1000 MHz

¸FSH-Z38

1300.7740.02

Active Directional Antenna

¸HE200

4050.3509.02

Isotropic Antenna, 30 MHz to 3 GHz for ¸FSH 3

¸TS-EMF

1158.9295.13

Near-Field Probe Set 

¸HZ-15

1147.2736.02

Preamplifier for ¸HZ-15

¸HZ-16

1147.2720.02

Accessories and ordering information

23

Handheld Spectrum Analyzer ¸FSH

Summary of Contents for FSH3

Page 1: ...Third Edition June 2006 Handheld Spectrum Analyzer FSH FSH3 100 kHz to 3 GHz FSH6 100 kHz to 6 GHz...

Page 2: ...and so can handle anything from the installation or maintenance of a mobile radio base station up to on site fault location in RF cables as well as development and service an extensive range of applic...

Page 3: ...The FSH has been designed as a robust portable spectrum analyzer that can be used in the field The FSH can of course also be used on the lab bench The FSH has an adjust able fold out stand to positio...

Page 4: ...Simple menu based operation via softkeys Memory for up to 256 traces and setups Direct printout of measure ment results Selection of following functions Marker Delta marker Noise marker Frequency cou...

Page 5: ...model 13 100 Hz to 1 MHz models 03 and 23 100 Hz to 1 MHz Video bandwidths 10 Hz to 1 MHz Displayed average noise level typ 114 dBm 1 kHz model 13 typ 135 dBm 100 Hz models 03 and 23 typ 135 dBm 100...

Page 6: ...are available as accessories for high precision terminating power measurements up to 8 GHz or 18 GHz as well as for directional power measurements up to 4 GHz The following tables show possible confi...

Page 7: ...nto the FSH using the FSH View software Channel power measurements The FSH determines the power of a definable transmission channel by means of the channel power measurement function A channel power m...

Page 8: ...The channel tables are generated with the FSH View software and loaded into the FSH For a few TV transmitter and mobile radio standards the tables are predefined In addition the CISPR bandwidths 200...

Page 9: ...r and the matching of transmitter system antennas under operating conditions The power sensors measure average power up to 120 W and normally eliminate the need for any extra attenuators They are comp...

Page 10: ...ments Compared to scalar measurements the optional FSH K2 vector measure ment significantly in creases measurement accuracy and dynamic range for transmission and reflection measurements This is possi...

Page 11: ...synchronize to antenna diversity Data transfer between FSH and PC interface cables and software are supplied with the instrument FSH with FSH Z2 VSWR bridge FSH with Directional Power Sensor FSH Z44...

Page 12: ...ted only by the size of the hard disk of the controlling PC Automatic storage of measurement results at selectable intervals Generation of cable data with a built in cable editor downloading to the FS...

Page 13: ...Hz from carrier 120 dBc 1 Hz Sweep time span 0 Hz 1 ms to 100 s span 0 Hz 20 ms to 1000 s min 20 ms 600 MHz Bandwidths Resolution bandwidths 3 dB model 13 1 3 10 30 100 200 300 kHz 1 MHz model 03 23 m...

Page 14: ...3 06 and 26 120 dBm typ 125 dBm 115 dBm typ 120 dBm 120 dBm typ 125 dBm 115 dBm typ 120 dBm 115 dBm typ 120 dBm 105 dBm typ 110 dBm Inherent spurious reference level 20 dBm f 30 MHz RBW 100 kHz 80 dBm...

Page 15: ...equired level from 50 10 dBm Outputs AF output 3 5 mm mini jack Output impedance Open circuit voltage 100 adjustable up to 1 5 V Tracking generator only models 13 23 26 Frequency range 5 MHz to 3 GHz...

Page 16: ...48 mm 31 mm 170 mm connecting cable 1 5 m Weight 0 3 kg Directional Power Sensor FSH Z14 Frequency range 25 MHz to 1 GHz Power measurement range 30 mW to 300 W VSWR referenced to 50 W 1 06 Power handl...

Page 17: ...001 duty cycle 0 1 video bandwidth 4 kHz 200 kHz 600 kHz 3 of measured value 0 05 W at burst width 200 s 3 of measured value 0 20 W at burst width 4 s 7 of measured value 0 40 W at burst width 2 s 1...

Page 18: ...sured value 0 09 dB Temperature coefficient 200 MHz to 300 MHz 300 MHz to 4 GHz 0 40 K 0 017 dB K 0 25 K 0 011 dB K Peak envelope power Power measurement range DAB DVB T cdmaOne CDMA2000 3GPP WCDMA Vi...

Page 19: ...dB 1 15 1 22 Forward power Frequency 0 2 0 4 0 7 1 23 4 GHz 100 200 400 600 800 1000 AVG 35 C to 50 C VSWR 3 PEAK max 10 ms VSWR 3 AVG 10 C to 35 C VSWR 1 5 AVG 10 C to 35 C VSWR 3 dB 0 5 10 15 20 25...

Page 20: ...output N male Test port N female Control interface 7 contact connector type Binder Calibration standards FSH Z29 Z30 Z31 FSH Z28 Short open N male 50 load N male Impedance 50 Return loss DC to 3 GHz 3...

Page 21: ...typ 40 dB typ 55 dB typ 35 dB typ 50 dB Reflection measurements only with FSH3 model 13 or 23 FSH6 model 26 and FSH Z2 Frequency range 10 MHz to 3 GHz 10 MHz to 3 GHz Display range of return loss 10...

Page 22: ...dB test case 6 2 2 in line with 3GPP 25 141 Measurement range 40 dBm Ptotal 20 dBm Ptotal 20 dB PCPICH Ptotal Measurement uncertainty Ptotal 20 dBm PCPICH Ptotal 1 5 dB typ 0 5 dB P CCPCH power SNR 3...

Page 23: ...s Shock meets EN60068 2 27 40 g shock spectrum RFI suppression meets EMC directive of EU 89 336 EEC and German EMC legislation Immunity to radiated interference Level display at 10 V m reference level...

Page 24: ...06 Handheld Spectrum Analyzer 100 kHz to 6 GHz with tracking generator and preamplifier FSH6 1145 5850 26 Accessories supplied External power supply battery pack built in USB optical cable headphones...

Page 25: ...pter FSH Z21 1300 7579 02 Serial Parallel Converter FSH Z22 1145 5880 02 Carrying Bag FSH Z25 1145 5896 02 Transit Case FSH Z26 1300 7627 02 Combined Short Open and 50 Load for VSWR and DTF calibratio...

Page 26: ...S REG NO 1954 QM Certified Environmental System ISO14001 DQS REG NO 1954 UM More information at www fsh rohde schwarz com Rohde Schwarz direct Tel 49 2203 807 800 Fax 49 2203 807 66 E mail Direct rohd...

Reviews: