3GPP FDD code domain power BTS/Node B measurement (only with R&S®FSH-K 1300.633.02 and ¸FSH 3 model .23)
6)
Frequency range
10 MHz to 3 GHz
–
Carrier frequency uncertainty
(test case 6.3 in line with
3GPP 25.141)
–
Measurement range
±1 kHz
–
Measurement uncertainty
SNR > 30 dB
< 50 Hz +
Δ
f
ref
7)
(
σ
= 20 Hz)
–
Total power
SNR > 30 dB
(test case 6.2.1 in line with
3GPP 25.141)
–
Measurement range
frequency > 1 MHz
+20 °C to +30 °C
–60 dBm < P
total
< 20 dBm
–
Measurement uncertainty
–40 dBm < P
total
< 20 dBm
P
REF_LEV
– 30 dB < P
total
< P
REF_LEV
+ 3 dB
±1.5 dB, typ. 0.5 dB
–
CPICH power
SNR > 30 dB
(test case 6.2.2 in line with
3GPP 25.141)
–
Measurement range
–40 dBm < P
total
< 20 dBm
P
total
– 20 dB < P
CPICH
< P
total
–
Measurement uncertainty
– P
total
–20 dBm < P
CPICH
< P
total
±
1.5 dB, typ. 0.5 dB
–
P-CCPCH power
SNR > 30 dB
Measurement range
–40 dBm < P
total
< 20 dBm
P
total
– 40 dB < P
PCCPCH
< P
total
–
Measurement uncertainty
P
total
–20 dBm < P
PCCPCH
< P
total
±1.5 dB, typ. 0.5 dB
–
PSCH/SSCH power
SNR > 30 dB
–
Measurement range
–40 dBm < P
total
< 20 dBm
P
total
– 30 dB < P
SCH
< P
total
–
Measurement uncertainty
P
total
–20 dBm < P
PSCH
< P
total
±2.5 dB, typ. 1.5 dB
–
Symbol EVM
Measurement range
3 % < EVM
symbol
< 25 %
–
Measurement uncertainty
3 % < EVM
symbol
< 10 %
typ. ±2.5 %
–
10 % < EVM
symbol
< 20 %
typ. ±3 %
Residual EVM
symbol
typ. 3 %
Handheld Spectrum Analyzer ¸FSH
20
6)
As of serial no. 103500.
7)
Δ
f
ref