OM-RCS-24 SERIES CHEESER STATION

4.   Place wire rack on the rack brackets.    

 

 

 

 
 5.  Assure the rack is placed between the pins on the rack brackets. 

 

  

 

 
6.  Uncap the dustproof cap from the receptacle located in the backsplash of the 

Cheeser 

Station. 

    

 
7.   Plug in the platform plug/cord into the receptacle in the backsplash. Line up 

the latch of the platform plug/cord to the receptacle as shown and push until 

it clicks in place.   

 

 

 

 

REFRIGERATION CONTROL

1.  To power on the base, press and hold the base control power button until the 

LED display turns on. To power on the rail, press and hold the rail control power 

button until the LED display turns on. The power controls are located above the 

louver panel.

2.  To power off the base press and hold the base control power button until the 

LED display turns off. To power off the rail press and hold the rail control power 

button until the LED display turns off. The power controls are located above the 

louver panel.

3.  The clean-out port valve for the upper rail is found behind the hinged vented 

door. The rail may be drained by placing a pan under the clean-out port valve 

and opening the valve (see Nightly Shut Down of Prep Rail).

 
 

Cleanout Port Extension 

                   Cleanout Port Valve

MORNING STARTUP OF PREP RAIL

1.  Unit cleaning may be performed at this time.
2.  Turn on unit. See item #2 under the Refrigeration Control section above for 

powering on the rail.

3.  Allow a minimum 45 minutes for your unit to cool down before loading product. 

A uniform frost pattern will appear on side walls and bottom of prep rail area.

4.  Load the product and proceed with food preparation. NOTE: Product entering 

unit must be at 35°F +/- 2°F.

NIGHTLY SHUT DOWN OF PREP RAIL

1.  Remove product from unit at the end of the day’s preparation.
2.  Turn off unit.  See item #3 under the Refrigeration Control section above for 

powering on the rail. 

3.  Unit cleaning may be performed at this time if the frost has melted off the surface.
4.  Once defrosted, the rail drain may be opened to remove any water that has 

resulted from the defrosting procedure.

WARNING:  IT IS RECOMMENDED TO ONLY MAKE CHANGES OF 2 DEGREE INCREMENTS 

AT A TIME. ALLOW FOR THE UNIT TO OPERATE 24 HOURS BETWEEN 

ADJUSTMENTS. IF THE 2 DEGREE ADJUSTMENT IS NOT ENOUGH ANOTHER 

ADJUSTMENT CAN BE MADE. IF THE SETTINGS NEED TO GO ABOVE OR 

BELOW THIS POINT THERE MAY BE OTHER CONTRIBUTING FACTORS AS 

TO THE CAUSE OF THE TEMPERATURE VARIANCES, PLEASE CONTACT THE 

FACTORY AT 1-800-621-8560.

AMBIENT CONDITIONS

Unit is designed for normal operating temperatures between 70° F (21°C) - 86°F 
(32°C). Operating outside of those temperatures may cause premature product 
wear or failure.
Unified Brands has attempted to preset the temperature control to ensure that 
your unit runs at an optimum temperature, but due to varying ambient conditions, 
including elevation, food type and your type of operation, you may need to alter 
this temperature using control adjustment until desired temperature is reached. 

Summary of Contents for RCS-24

Page 1: ...t you do so at once Manufacture Service Questions 888 994 7636 RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Due to a continuous program of product improvement Unified Brands reserves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will ...

Page 2: ...temperature If temperature adjustments are required the control is located on the front panel Confirm that the units is holding the desired temperature 7 If unit has drawers check drawer to ensure the drawer slides freely and fully extents along with seating in the cabinet properly when closed 8 Refer to the front of this manual for serial number location Please record this information in your man...

Page 3: ...he refrigerated supply bin 2 Determine the location of the Cheeser Station and move into position above image shows the Cheeser Station on the left for left to right operation INSTALLATION OF RCS 24 RACK ASSEMBLY 1 Insert cheese bin inside the refrigerated cold well The bins slanted wall should be placed towards the back 2 Set the rack support assembly in the cold well opening with the front suppo...

Page 4: ...g on the rail 3 Allow a minimum 45 minutes for your unit to cool down before loading product A uniform frost pattern will appear on side walls and bottom of prep rail area 4 Load the product and proceed with food preparation NOTE Product entering unit must be at 35 F 2 F NIGHTLY SHUT DOWN OF PREP RAIL 1 Remove product from unit at the end of the day s preparation 2 Turn off unit See item 3 under t...

Page 5: ...repeatedly to return to exit and return to the home screen MAINTENANCE WARNING DO NOT USE SHARP UTENSILS AND OR OBJECTS WARNING DO NOT USE STEEL PADS WIRE BRUSHES SCRAPERS OR CHLORIDE CLEANERS TO CLEAN YOUR STAINLESS STEEL CAUTION DO NOT USE ABRASIVE CLEANING SOLVENTS AND NEVER USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL WARNING DO NOT PRESSURE WASH EQUIPMENT AS DAMAGE TO ELECTRICAL COM...

Page 6: ...SS STEEL INCLUDE THE FOLLOWING JOB CLEANING AGENT COMMENTS Routine cleaning Soap ammonia detergent Medallion Apply with a sponge or cloth Fingerprints and smears Arcal 20 Lac O Nu Ecoshine Provides a barrier film Stubborn stains and discoloration Cameo Talc Zud First Impression Rub in the direction of the polish lines Greasy and fatty acids blood burnt on foods Easy Off Degrease It Oven Aid Excell...

Page 7: ...orn or out of place Inspect the gasket for wear and position Incorrect set point Adjust control set point Warm product introduced to cabinet Pre chill product 37ºF Ice on the coil Initiate manual defrost Unit noisy Ice on the coil Initiate manual defrost Unit does not defrost Excessive ice on the coil Initiate manual defrost TROUBLESHOOTING WEIGH SCALE PLATFORM SYMPTOM POSSIBLE CAUSE PROCEDURE Uni...

Page 8: ...he condition of load cell connections check for damaged load cell ZERO ERROR The weight reading is beyond the limit set for Zero operation The operation of the ZERO key is limited in the setup during installation The indicator cannot be Zeroed at this weight Increase the Zero Range Z RANGE or use the TARE key instead STABLE ERROR Scale motion has prevented a ZERO TARE or PRINT operation from occur...

Page 9: ...ent set up operations or service please call 888 994 7636 In addition please review the sales terms and conditions set forth below IMPORTANT NOTICE WARRANTIES LIMITATIONS ON WARRANTIES AND LIMITATION OF REMEDIES The following Warranties Limitation on Warranties and Limitation of Remedies are included in the terms of sale for this product Please read this entire warranty and all warranty modificati...

Page 10: ...OLYPROPYLENE 375 LB CAPACITY 6 2 HD CST1705 CASTER 4 5 IN W BRAKE POLYPROPYLENE 375 LB CAPACITY 7 1 HD RCK1902 RACK SS PREP 18in x 16 25in x 0 25in ROD 8 1 HD PAN1901 PAN CHEESE BIN 19 5 X 24 X 6 DEEP BLACK ABS 9 1 RP PNL2107 PANEL APRON REPLACEMENT PART 10 1 RP DOR2101 CONDENSING UNIT DOOR CHEESER UNIT LT HINGED REPLACEMENT PART 11 1 RP BCK2102 BACK FINISH 24 REPLACEMENT PART 12 4 HD BMP034 BUMPE...

Page 11: ...EL SCALE INDICATOR W SEE THROUGH WINDOW 21 1 EL SEN1801 SENSOR PHOTOELECTRIC SWITCH 12M CYLINDRICAL DC 10 30V 22 1 PP LBL1956 LABEL SCALE TARE SENSOR 1X3 UNIVERSAL 23 1 RP DSN002 SCREEN DRAIN LARGE 2 24 1 EL SCL2101 SCALE CONTROL DISPLAY BOARD W TERMINATION CONNECTOR 25 1 RP SCL2102 BRACKET WEIGH SCALE DISPLAY BOARD WITH SCREWS 26 1 EL TRN1801 TRANSFORMER 90W CONSTANT VOLTAGE CURRENT CLASS 2 LPF 9...

Page 12: ...HINGED SHEET METAL ONLY 31 1 HD HDL0103 HANDLE RECESSED DOOR PULL BLACK PLASTIC 32 1 FA NUT0124 NUTSERT 1 4 20 ALUM KPNG RIVNUT 33 1 HD PIN020B PIN 7 16x5 8 W SCW BOLT ONLY J32 X002 34 1 HD PIN020P PIN 7 16x5 8 W SCW PIN ONLY J32 X001 35 1 RP DOR2103 HINGED DOOR MNTING BRACKET HINGED LEFT REPLACEMENT PART 36 7 FA SCW3075T SCREW 10x3 4 THP SMS SS 37 1 FA BLT4062 BOLT 1 4 20x3 4 H H B 18 8 HCYK HEX ...

Page 13: ...ON 39 1 RP DRN2101 PIPE 1 5 PVC S40 120mm LONG REPLACEMENT PART 40 1 RP DRN2102 BRACKET DRAIN EXTENSION WITH MOUNTING SCREWS 41 1 PB ADP9903 ADAPTOR 1 1 2 PVC FIP X GLUE PVCAF150 42 1 RP DRN2103 PIPE 1 5IN PVC 76mm LONG 43 1 PB ELB2001 ELBOW 1 1 2in PVC 40 45 DEGREE STREET SP x SLIP 44 1 PB VLV0901 VALVE 1 1 2 GATE VALVE PVC SLIP x SLIP 6101 NOT SHOWN ...

Page 14: ...EPLACEMENT PART 50 2 RP SCL2105 CAP SCALE LOAD CELL BRACKET REPLACEMENT PART 51 2 RP SCL2106 MOUNTING SCALE BRACKET REPLACEMENT PART 52 8 FA BLT0106 BOLT 1 4 20 x 3 4 T H P 18 8 M6KF WITH LIGHT NYLON PATCH 53 2 RP SCL2107 MOUNTING BRACKET RACK WITH PINS REPLACEMENT PART 54 1 HD RCK1904 RACK CHEESER STATION SIZE 18 1 X 18 3 INCH 55 1 HD RCK1902 RACK SS PREP 18in x 16 25in x 0 25in ROD 56 8 RP SCL21...

Page 15: ...48 66 1 RP HRN2101 WIRE HARNESS SINGLE COMPRESSOR CONDENSING UNIT FAN AND CONTROL 67 1 RP CAP014 CAP TUBE 036 X 96 W DRIER TO INCLUDE 1 042 FILTER DRIER 68 1 RF CMP1801SC START COMPONENTS 1 5HP R290 EMBRACO 115 60 EMX3115U 69 1 RF CMP1801 COMPRESSOR 1 5HP 115V 60HZ R290 EMBRACO EMX3115U 70 4 HD PIN0601 PIN HAIR COTTER WIRE 072D L 1 1 8 ZINC PLATED 71 1 RF CNT1801 PROBE COND COIL YELLOW CFA 290 72 ...

Page 16: ...16 OM RCS 24 SERIES CHEESER STATION Wiring Diagram CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 ...

Page 17: ...17 OM RCS 24 SERIES CHEESER STATION Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...

Reviews: