OM-RCS-24 SERIES CHEESER STATION

INSTALLATION

CAUTION:  THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT.  USE CAUTION 

WHEN HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER.  

AVOID DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A 

LEAK. 

WARNING:  FAILURE TO FOLLOW INSTALLATION GUIDELINES AND 

RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.

WARNING:  IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE. 

CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE 

FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON 

THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING 

VOLTAGE LIMITS WILL VOID THE WARRANTY.

 

THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL 

NOT OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 
104V.

WARNING:  IT IS IMPORTANT THAT A VOLTAGE READING BE MADE AT THE COMPRESSOR 

MOTOR ELECTRICAL CONNECTIONS, WHILE THE UNIT IS IN OPERATION 

TO VERIFY THE CORRECT VOLTAGE REQUIRED BY THE COMPRESSOR IS 

BEING SUPPLIED.  LOW OR HIGH VOLTAGE CAN DETRIMENTALLY AFFECT 
OPERATION AND THEREBY VOID ITS WARRANTY.

WARNING:  EVAPORATOR FANS RUN CONTINUOUSLY WHILE THE BASE IS POWERED 

ON.

WARNING:  THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL, 

INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE 

SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15. 

SELECTING A LOCATION FOR YOUR NEW UNIT

The following conditions should be considered when selecting a location for 
your unit:
1. 

Floor Load: 

 The area on which the unit will rest must be level, free of vibration, 

and suitably strong enough to support the combined weights of the unit plus 
the maximum product load weight. All casters must be in contact with the floor 
to support the weight. Casters may require shims in order for the caster to be 
in contact with the floor. NOTE:  If there is a question pertaining to weight load 
limits, consult the factory at 1-888-994-7636.

2. 

Clearances:

  Unit shall have a clearance of 0 inches at the top, 0 inches at 

the rear and 0 inches at each side.

3. 

Ventilation:

  The air cooled self contained unit requires a sufficient amount 

of cool clean air.  Avoid surrounding your unit around other heat generating 
equipment and out of direct sunlight.  Also, avoid locating in an unheated 
room or where the room temperature may drop below 70° F (21°C) or above 
86°F (32°C). Do not place any object that can block the ventilation exhaust 
from the machine compartment register.

INSTALLATION CHECKLIST

After the final location has been determined, refer to the following checklist prior 
to start-up:
1.  Check all exposed refrigeration lines to ensure that they are not kinked, 

dented, or rubbing together or rubbing against any steel.

2.  Check all visible components for any potential damage.
3.  Check that the condenser fan rotates freely without striking any stationary 

members.

4.  Unit must be property leveled; Check all legs or casters ensure they all are 

in contact with the floor while maintaining a level work surface.  Adjusting 
bullet feet height or shimming casters may be necessary if the floor is not 
level.  NOTE:  Damage to equipment may result if not followed.  Unified 
Brands is not responsible for damage to equipment if improperly installed.

5.  Plug unit into power source.  Unit will come on.  If unit does not turn on, refer 

to controller operation section of this manual to manually turn on the unit.

6.  Allow unit time to cool down to holding temperature. If temperature 

adjustments are required, the control is located on the front panel.  Confirm 
that the units is holding the desired temperature.

7.  If unit has drawers, check drawer to ensure the drawer slides freely and fully 

extents along with seating in the cabinet properly when closed.

8.  Refer to the front of this manual for serial number location.  Please record 

this information in your manual on page 1 now.  It will be necessary when 
ordering replacement parts or requesting warranty service.

9.  Allow your unit to operate for approximately 45 minutes before putting in 

food in the rail.  Allow 2 hours for base of the unit to cool down to storage 
temperature, prior to loading product. NOTE:  All motors are oiled and sealed.

ELECTRICAL SUPPLY

The wiring should be done by a qualified electrician in accordance with local 
electrical codes.  A properly wired and grounded outlet will assure proper 
operation.  Please consult the data tag attached to the compressor to ascertain 
the correct electrical requirements.  Supply voltage and amperage requirements 
are located on the serial number tag located on the rear interior wall. 

IMPORTANT - READ FIRST - IMPORTANT

EXTERIOR OF UNIT

NEAR EXPOSED REFRIGERANT TUBING

RISK OF FIRE OR EXPLOSION. 

DISPOSE OF PROPERLY IN 

ACCORDANCE WITH FEDERAL OR 

LOCAL REGULATIONS. 

FLAMMABLE REFRIGERANT USED.

PRECAUCIÓN 

RIESGO DE INCENDIO O EXPLOSIÓN. DESÉCHELO ADECUADAMENTE CONFORME 

A REGLAMENTOS FEDERALES O LOCALES. REFRIGERANTE INFLAMABLE UTILIZADO.

MISE EN GARDE

 RISQUE 

D’INCENDIE OU 

D’EXPLOSION. ÉLIMINER 

(or DISPOSER) 

CORRECTEMENT 

CONFORMÉMENT AUX 

RÉGLEMENTATIONS 

FÉDÉRALES OU LOCALES. 

RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ.

SB6.1.4 

LABEL DIMENSION:  6 in x 2.75 in 

PP LBL1704 REV B

CAUTION

RISK OF FIRE OR EXPLOSION DUE TO 

PUNCTURE OF REFRIGERANT TUBING; FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY. 

FLAMMABLE REFRIGERANT USED.

PRECAUCIÓN 

RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACIÓN DE LA TUBERÍA DE 

REFRIGERANTE; SIGA CUIDADOSAMENTE LAS INSTRUCCIONES DE MANEJO. REFRIGERANTE 

INFLAMABLE UTILIZADO.

MISE EN GARDE

 RISQUE 

D’INCENDIE OU 

D’EXPLOSION EN RAISON 

DE LA PERFORATION DU 

TUBE RÉFRIGÉRANT; 

SUIVEZ ATTENTIVEMENT 

LES INSTRUCTIONS DE 

MANIPULATION. 

RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ.

CAUTION

SB6.1.5

PP LBL1705 REV B

LABEL DIMENSION:  6.25 in x 2.8 in 

RISK OF FIRE OR EXPLOSION. FLAMMABLE 

REFRIGERANT USED. CONSULT REPAIR MANUAL 

/ OWNER’S GUIDE BEFORE ATTEMPTING TO 

INSTALL OR SERVICE THIS PRODUCT. ALL 

SAFETY PRECAUTIONS MUST BE FOLLOWED. 

PRECAUCIÓN 

RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. CONSULTE EL MANUAL DE REPARACIÓN / 

MANUAL DEL USUARIO ANTES DE INSTALAR O REPARAR ESTE PRODUCTO. DEBEN SEGUIRSE LAS PRECAUCIONES DE SEGURIDAD.

MISE EN GARDE 

RISQUE 

D’INCENDIE OU 

D’EXPLOSION. RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ. 

CONSULTER LE MANUEL DE 

RÉPARATION / GUIDE DE 

L’UTILISATEUR AVANT 

D’ESSAYER D’INSTALLER OU 

DE RÉPARER CE PRODUIT. 

TOUTES LES PRÉCAUTIONS 

DOIVENT ÊTRE RESPECTÉES.

SB6.1.3.b 

PP LBL1703 REVB

LABEL DIMENSION:  7.5 in x  5.36 in

SB6.1.3.a 

RISK OF FIRE OR EXPLOSION. FLAMMABLE 

REFRIGERANT USED. TO BE REPAIRED ONLY 

BY TRAINED SERVICE PERSONNEL. DO NOT 

PUNCTURE REFRIGERANT TUBING.

PELIGRO 

RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. DEBE SER REPARADO 

SOLAMENTE POR PERSONAL DE SERVICIO CAPACITADO. NO PERFORE LA TUBERÍA DEL REFRIGERANTE.

DANGER 

RISQUE 

D’INCENDIE OU 

D’EXPLOSION. 

RÉFRIGÉRANT 

INFLAMMABLE UTILISÉ. 

POUR ÊTRE RÉPARÉ QUE 

PAR UN TECHNICIEN 

QUALIFIÉ. NE PAS 

PERFORER LE TUBE 

RÉFRIGÉRANT.

CAUTION

DANGER

NEAR MACHINE COMPARTMENT AND NAMEPLATE

Image shown at right with grill door removed to show location of R290 labels.

Summary of Contents for RCS-24

Page 1: ...t you do so at once Manufacture Service Questions 888 994 7636 RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Due to a continuous program of product improvement Unified Brands reserves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will ...

Page 2: ...temperature If temperature adjustments are required the control is located on the front panel Confirm that the units is holding the desired temperature 7 If unit has drawers check drawer to ensure the drawer slides freely and fully extents along with seating in the cabinet properly when closed 8 Refer to the front of this manual for serial number location Please record this information in your man...

Page 3: ...he refrigerated supply bin 2 Determine the location of the Cheeser Station and move into position above image shows the Cheeser Station on the left for left to right operation INSTALLATION OF RCS 24 RACK ASSEMBLY 1 Insert cheese bin inside the refrigerated cold well The bins slanted wall should be placed towards the back 2 Set the rack support assembly in the cold well opening with the front suppo...

Page 4: ...g on the rail 3 Allow a minimum 45 minutes for your unit to cool down before loading product A uniform frost pattern will appear on side walls and bottom of prep rail area 4 Load the product and proceed with food preparation NOTE Product entering unit must be at 35 F 2 F NIGHTLY SHUT DOWN OF PREP RAIL 1 Remove product from unit at the end of the day s preparation 2 Turn off unit See item 3 under t...

Page 5: ...repeatedly to return to exit and return to the home screen MAINTENANCE WARNING DO NOT USE SHARP UTENSILS AND OR OBJECTS WARNING DO NOT USE STEEL PADS WIRE BRUSHES SCRAPERS OR CHLORIDE CLEANERS TO CLEAN YOUR STAINLESS STEEL CAUTION DO NOT USE ABRASIVE CLEANING SOLVENTS AND NEVER USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL WARNING DO NOT PRESSURE WASH EQUIPMENT AS DAMAGE TO ELECTRICAL COM...

Page 6: ...SS STEEL INCLUDE THE FOLLOWING JOB CLEANING AGENT COMMENTS Routine cleaning Soap ammonia detergent Medallion Apply with a sponge or cloth Fingerprints and smears Arcal 20 Lac O Nu Ecoshine Provides a barrier film Stubborn stains and discoloration Cameo Talc Zud First Impression Rub in the direction of the polish lines Greasy and fatty acids blood burnt on foods Easy Off Degrease It Oven Aid Excell...

Page 7: ...orn or out of place Inspect the gasket for wear and position Incorrect set point Adjust control set point Warm product introduced to cabinet Pre chill product 37ºF Ice on the coil Initiate manual defrost Unit noisy Ice on the coil Initiate manual defrost Unit does not defrost Excessive ice on the coil Initiate manual defrost TROUBLESHOOTING WEIGH SCALE PLATFORM SYMPTOM POSSIBLE CAUSE PROCEDURE Uni...

Page 8: ...he condition of load cell connections check for damaged load cell ZERO ERROR The weight reading is beyond the limit set for Zero operation The operation of the ZERO key is limited in the setup during installation The indicator cannot be Zeroed at this weight Increase the Zero Range Z RANGE or use the TARE key instead STABLE ERROR Scale motion has prevented a ZERO TARE or PRINT operation from occur...

Page 9: ...ent set up operations or service please call 888 994 7636 In addition please review the sales terms and conditions set forth below IMPORTANT NOTICE WARRANTIES LIMITATIONS ON WARRANTIES AND LIMITATION OF REMEDIES The following Warranties Limitation on Warranties and Limitation of Remedies are included in the terms of sale for this product Please read this entire warranty and all warranty modificati...

Page 10: ...OLYPROPYLENE 375 LB CAPACITY 6 2 HD CST1705 CASTER 4 5 IN W BRAKE POLYPROPYLENE 375 LB CAPACITY 7 1 HD RCK1902 RACK SS PREP 18in x 16 25in x 0 25in ROD 8 1 HD PAN1901 PAN CHEESE BIN 19 5 X 24 X 6 DEEP BLACK ABS 9 1 RP PNL2107 PANEL APRON REPLACEMENT PART 10 1 RP DOR2101 CONDENSING UNIT DOOR CHEESER UNIT LT HINGED REPLACEMENT PART 11 1 RP BCK2102 BACK FINISH 24 REPLACEMENT PART 12 4 HD BMP034 BUMPE...

Page 11: ...EL SCALE INDICATOR W SEE THROUGH WINDOW 21 1 EL SEN1801 SENSOR PHOTOELECTRIC SWITCH 12M CYLINDRICAL DC 10 30V 22 1 PP LBL1956 LABEL SCALE TARE SENSOR 1X3 UNIVERSAL 23 1 RP DSN002 SCREEN DRAIN LARGE 2 24 1 EL SCL2101 SCALE CONTROL DISPLAY BOARD W TERMINATION CONNECTOR 25 1 RP SCL2102 BRACKET WEIGH SCALE DISPLAY BOARD WITH SCREWS 26 1 EL TRN1801 TRANSFORMER 90W CONSTANT VOLTAGE CURRENT CLASS 2 LPF 9...

Page 12: ...HINGED SHEET METAL ONLY 31 1 HD HDL0103 HANDLE RECESSED DOOR PULL BLACK PLASTIC 32 1 FA NUT0124 NUTSERT 1 4 20 ALUM KPNG RIVNUT 33 1 HD PIN020B PIN 7 16x5 8 W SCW BOLT ONLY J32 X002 34 1 HD PIN020P PIN 7 16x5 8 W SCW PIN ONLY J32 X001 35 1 RP DOR2103 HINGED DOOR MNTING BRACKET HINGED LEFT REPLACEMENT PART 36 7 FA SCW3075T SCREW 10x3 4 THP SMS SS 37 1 FA BLT4062 BOLT 1 4 20x3 4 H H B 18 8 HCYK HEX ...

Page 13: ...ON 39 1 RP DRN2101 PIPE 1 5 PVC S40 120mm LONG REPLACEMENT PART 40 1 RP DRN2102 BRACKET DRAIN EXTENSION WITH MOUNTING SCREWS 41 1 PB ADP9903 ADAPTOR 1 1 2 PVC FIP X GLUE PVCAF150 42 1 RP DRN2103 PIPE 1 5IN PVC 76mm LONG 43 1 PB ELB2001 ELBOW 1 1 2in PVC 40 45 DEGREE STREET SP x SLIP 44 1 PB VLV0901 VALVE 1 1 2 GATE VALVE PVC SLIP x SLIP 6101 NOT SHOWN ...

Page 14: ...EPLACEMENT PART 50 2 RP SCL2105 CAP SCALE LOAD CELL BRACKET REPLACEMENT PART 51 2 RP SCL2106 MOUNTING SCALE BRACKET REPLACEMENT PART 52 8 FA BLT0106 BOLT 1 4 20 x 3 4 T H P 18 8 M6KF WITH LIGHT NYLON PATCH 53 2 RP SCL2107 MOUNTING BRACKET RACK WITH PINS REPLACEMENT PART 54 1 HD RCK1904 RACK CHEESER STATION SIZE 18 1 X 18 3 INCH 55 1 HD RCK1902 RACK SS PREP 18in x 16 25in x 0 25in ROD 56 8 RP SCL21...

Page 15: ...48 66 1 RP HRN2101 WIRE HARNESS SINGLE COMPRESSOR CONDENSING UNIT FAN AND CONTROL 67 1 RP CAP014 CAP TUBE 036 X 96 W DRIER TO INCLUDE 1 042 FILTER DRIER 68 1 RF CMP1801SC START COMPONENTS 1 5HP R290 EMBRACO 115 60 EMX3115U 69 1 RF CMP1801 COMPRESSOR 1 5HP 115V 60HZ R290 EMBRACO EMX3115U 70 4 HD PIN0601 PIN HAIR COTTER WIRE 072D L 1 1 8 ZINC PLATED 71 1 RF CNT1801 PROBE COND COIL YELLOW CFA 290 72 ...