CustomAir

®

by RAMVAC®

User Guide

INSTALLATION DATA

 

 

 

 

• 

Indoor use only, in a dust free, climate controlled room.

 

 

• 

DO NOT

 install in an enclosed area where ambient temperature could exceed temperature specifications of

 

 

  below 0º C / 35º F or above 40º C / 104º F while the compressor is running.

 

 

•  Maintain minimum 6” clearance on sides, back, and top of all compressors.  Maintain 12” clearance in front of compressor.

 

 

•  On the 1029T compressor maintain a 12” clearance on left side for electrical service.

 

 

•  Compressors are equipped with 4 adjustable rubber feet, to ensure unit stands firmly on the floor.

 

WARNING:

 

DO NOT 

install on surfaces with more than a 5º incline. 

 

 

WARNING: 

 

To prevent tipping during transport securely fasten unit to shipping pallet.

 

CAUTION:  

Danger of fire or explosion when using flamable substances.

 

CAUTION:

 

Never leave children unattended when compressor is in use.

 

 

 

 

• 

Follow NEC, NFPA 99C, and all local codes.

 

 

• 

Compressors are shipped with the appropriate electrical cord with plug.

 

 

• 

Qualified personnel must install electrical outlets.

 

 

• 

Electrical cicuit is a dedicated 20 amp circuit.

 

 

 

• 

C1 Control and Motor Control Box for the 1029T compressor use a 20 amp time delay fuse.

 

 

• 

See “Specifications” for more electrical information.

 

WARNING:  

Electrical shock could occur as a result of improper grounding.

 

 

• 

This product must be grounded according to NEC regulations and local codes.

 

WARNING:   

Always

 

turn off compressor and remove power plug from outlet when servicing.

 

 

CAUTION: 

Use of an extension cord is not advisable.

  

An undersized extension cord will cause

 

 

   

a drop in line voltage and loss of power.  Overheating will result.

 

 

 

 

• 

Attach drain tubing to fitting on bottom of coalescing filter and direct it into floor drain for disposal of water.

 

 

• 

Connect compressor air outlet to facility plumbing with provided supply hose.

 

 

 

Note:  Pressure regulator is customer supplied.

 

 

• 

Connect Fresh Air Intake to external air source per NFPA 99C recommendations.

 

WARNING:   

Property  damage and / or personal injury may result if directions are not followed or 

 

 

   

  OEM parts are not used.

 

CAUTION:   

Connect only equipment suitable for listed maximum pressure of the compressor.

 

 

   

  If vital equipment is used, an alternative air source should be available in case of equipment failure.

Plumbing Connections

Electrical

Placement

Summary of Contents for CustomAir 1000 Series

Page 1: ...ssors to be operated simultaneously in larger clinics CustomAir compressors are designed using trouble free solid state transducers in lieu of mechanical pressure switches to ensure dependability and...

Page 2: ...b A w sound cover CFM output at peak airflow SCFM at 100 psi Pump up cycle time sec from 80 100 psi Tank size in gallons Filter Dryer Duty Dryer Dew Point Total HP 1022 2 3 100 208 253 5 1 136 24 x 20...

Page 3: ...Dental Compressed Air System USER GUIDE Installation and Maintenance Manual For 1000 Series with C1 Control...

Page 4: ...nal invitation to visit our manufacturing facility in the beautiful Black Hills of South Dakota Matt Olson General Manager RAMVAC Dental Products Inc 800 5 RAMVAC 800 572 6822 Safety and Regulatory In...

Page 5: ...e Page 8 Filter Maintenance Page 9 Inspecting Dryer Page 10 Testing Safety Valves Page 10 Testing Compressor for Leaks Page 10 Speci cations Page 11 Troubleshoooting Page 12 Warranty Inside back cover...

Page 6: ...ly contact the freight carrier and supplier 3 Remove lag screws holding the compressor to shipping pallet 4 Verify additional parts shipped with the compressor a Additional parts shipped with all comp...

Page 7: ...ctrical outlets Electrical cicuit is a dedicated 20 amp circuit C1 Control and Motor Control Box for the 1029T compressor use a 20 amp time delay fuse See Specifications for more electrical informatio...

Page 8: ...Filter Coalescing Filter Heat Exchanger and Fan Desiccant Dryer Cartridge Pressure Gauge Safety valve Safety Valve Model 1025D is pictured Other models have identical features with the exception of m...

Page 9: ...particulate lter to remove any remaining particulates from the air It is then collected in the tank where a pressure gauge displays the tank air pressure The tank pressure is monitored by a pressure...

Page 10: ...1 Turns motors off at 100 psi 2 Turns motors on at 80 psi 2nd motor will start with a 1 second delay Provides a 24VAC low voltage signal to the remote panel Accepts the remote switch input Controls th...

Page 11: ...rminals Toggle Switch or other non illuminated switch option Vac Switch Vac Light Common F 24 VAC G 24 VAC H AC Common Illuminated Remote Switch C1 Controller Terminals Note Maximum wire length for lo...

Page 12: ...commended levels High temperatures will shorten the life of the air compressor Follow the recommended preventative maintenance schedule Preventive Maintenance Schedule This is a recommended schedule f...

Page 13: ...nd remove 5 Remove lter by turning completely out 6 Install new 5 micron lter 7 Position lter bowl push up slightly and turn into place 8 Plug power cord into outlet 9 Return compressor to service Rep...

Page 14: ...e compressor is still running pull ring on safety valve Note A loud burst of escaping air will be heard when air is released from the safety valve 3 If no air comes out of safety valve the valve is de...

Page 15: ...8 FRN 25 UNIT POWER CONSUMPTION 5 1 amps 12 0 amps 5 9 amps 8 4 amps 9 5 amps 15 4 amps UNIT DIMENSIONS w x d x h 24 x 20 5 x 28 24 x 20 5 x 26 5 24 x 20 5 x 26 5 24 x 20 5 x 26 5 27 x 22 x 36 WEIGHT...

Page 16: ...s 4 Dryer malfunction 5 Valves sticking 1 See Test Compressor for Leaks 2 Test facility air lines for leaks 3 Replace intake lters 4 Contact RAMVAC 5 Contact RAMVAC Compressor gets too hot 1 Ambient t...

Page 17: ...acuum System 2 Years from date of installation RAMVAC Vacuum Pumps only 10 Years from date of installation RAMVAC OWL 2 Years from date of installation CustomAir by RAMVAC 6 Years 4200 hours from date...

Page 18: ...Brand of the The Integrated Supplier PHONE 866 DTE INFO www dentalez com SOF_7 5 1 07 04 Effective date 28 Sep 07 2007 RAMVAC Dental Products All rights reserved No part of this publication may be co...

Reviews: