11
RAM 100 • 1000 • 5500
RAMSET
www.ramsetinc.com
5
Outside
Photo Eye
Inside Photo Eye
Back-Plane Photo Eye
Figure 12
LOOP SENSOR INSTALLATION
Reversing Loops
on the ground floor, prevents gate from closing when vehicle is in loop area.
Exit Loops
on the ground floor, opens gate when vehicle crosses loop area.
Ramset Gate Operators should always be installed with non-contact sensing devices such as
Loop Detectors, Photo Eyes or the equivalent.
A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge
device or equivalent) is required on each individual installation to comply with UL325.
WARNING
To adjust gate travel, depress spring loaded bracket and spin each Adjustment Nut to the required position
(Figure 13, 14). L.E.D. must turn on to indicate position open or close when limit switch is activated by limit
switch adjustment nut.
GATE TRAVEL ADJUSTMENT
TURN POWER OFF BEFORE ATTEMPTING ADJUSTMENT
Adjustment
Nuts
Depress spring loaded bracket
to free adjustment nuts
RAM 1000 / 5500
Depress spring loaded bracket
to free adjustment nuts
RAM 100
Adjustment
Nuts
Figure 13
Figure 14