28
RAMSET
www.ramsetinc.com
TROUBLESHOOTING TABLE
CONDITION
POSSIBLE CAUSES
SOLUTION
NO LIGHTS ARE ‘ON’.
1. Circuit breaker popped.
2. 1/2 amp. fuse blown.
3. Power supply damaged on
Control Board.
1. Reset circuit breaker.
2. Replace 1/2 amp. fuse.
3. Return Control Board for repair.
GATE MOVES A COUPLE
OF FEET AND THEN
REVERSES.
1. E.R.D. too sensitive.
1. A) for 1/2 hp motors: turn dip switch
“A” 4 ‘On’.
B) for 3/4 hp motors: turn dip switch
“B” 8 ‘On’.
“EXIT” L.E.D. IS ALWAYS
‘ON’.
1. Faulty accessory connected to
the “Exit”.
1. Disconnect all accessories, including
plug-ins, using the “Exit” input. If
problem persist, contact Ramset.
“REV LOOP” L.E.D.
ALWAYS ‘ON’.
1. Faulty accessory connected
to the “Rev Loop”.
1. Disconnect all accessories, including
plug-ins, using the “Rev Loop” input.
If problem persist, contact Ramset.
“RADIO” L.E.D. ALWAYS
‘ON’.
1. Stuck button on Transmitter
2. Faulty Receiver.
1. Check all transmitters.
2. Remove receiver.
If problem persist, contact Ramset.
GATE DOESN’T OPEN.
1. Radio L.E.D. ‘On’.
2. 10 amp. fuse blown.
3. Opening accessory not
functioning.
1. See above symptoms/solutions.
2. Check/replace 10 amp. fuse.
3. Check/replace opening accessory.
GATE DOESN’T CLOSE.
1. No lights are ‘On’.
2. Exit, Rev Loop, Radio L.E.D.‘On’.
3. 10 amp. fuse blown.
4. Thermal/overload button
popped on motor.
1. See above symptoms/solutions.
2. See above symptoms/solutions.
3. Check/replace 10 amp. fuse.
4. Reset thermal/overload button on
the back of the motor.
GATE DOESN’T CLOSE
AUTOMATICALLY.
1. Dip switches “A” 1-3 are all ‘Off’.
2. Dip switch not on all the way.
1. Set dip switches “A” 1-3 for auto close.
2. Turn off dip switches “A” 1-3, then turn
the appropriate switches back ‘On’.
GATE AUTOMATICALLY
OPENS, BUT DOESN’T
AUTOMATICALLY CLOSE.
1. Motor direction wrong.
1. Turn on dip switch “C” 7 (left/right).
RADIO/RECEIVER HAS
NO RANGE.
1. Signal blocked.
2. Area not suitable for type of
Receiver.
1. Make sure antenna is in proper
position & not shorted to chassis.
2. May need to change to long range
receiver.
9116 De Garmo Ave.
Sun Valley, CA 91352
Tel: (818) 504-2533 • Fax: (818) 504-1141
www.ramsetinc.com