background image

5

Electrical Connections 

Installation continued  

Charging  Status  

The charger will examine  

connected batteries’ voltage

GREEN

FLASHING

RED

ORANGE

RED

FLASHING

GREEN

Indicator Lights During Charge:

 SOLID GREEN

Battery pack voltage above 40VDC 

Battery pack fully charged

1 SEC GREEN 

FLASH

Battery pack is between 38  

and 40VDC

SOLID ORANGE

Battery pack is between 33  

and 38VDC

1 SEC RED FLASH

Battery pack between 27  

and 33VDC

SOLID RED

Battery pack voltage below 27VDC

½ SEC RED FLASH

Battery pack failed to charge in 9 

hours, or Battery pack less than 

6VDC

OFF

No AC or DC input power or no  

battery pack

Route and attach AC power cable plug to appropriate AC power receptacle, or route and 
attach DC power cable to an appropriate 12V DC or 24V DC power block.
Three models to support various input power application: 85-260V with NEMA plug,  
85-260V with Schuko plug, and 12-24DC.
AC Models: Insert AC plug into the appropriate AC power receptacle. The AC input battery 
charger models are built around a universal (85 - 260AC, 50 / 60Hz) input power supply.  
Only the AC plug determines the input voltage to be 115VAC or 230VAC.
DC Models: Will work with 10-30VDC input.
Charger is not equipped with a power switch and there is no reason to cycle power ON & 
OFF.
Charger automatically turns ON when input power is applied to the charger. Both Battery 
status LEDS will flash at a rate of two flashes per second for 10 seconds and then turn OFF 
until battery pack(s) have been connected to charger.

   Determine appropriate through hole drill bit for select screws

   Drill four holes at indicated mounting locations, on the drill template and tap holes if  

  required

   Install screws with screw head about 1/8

"

 above mounting surfaces

   Hang charger onto the four screws

   Tighten screws to securely hold charger in place

Batteries should not be stored for longer than 12 months without charging, to maintain 

“longterm reliability.”

Refer to pages 8 and 9 for Drill Template illustration

Summary of Contents for R2C-5500AC

Page 1: ... Group San Diego Luxembourg Dubai Ningbo Owner s Manual R2C 5500AC Dual Battery Charger 115VAC Input R2C 5500AC230 Dual Battery Charger 230VAC Input R2C 5500DC Dual Battery Charger 12 24VDC Input Model Numbers ...

Page 2: ...f the charger is only guaranteed if the safety and operating information are carefully read and adhered to Do not use any chargers in an explosive environment such as in the vicinity of flammable liquids gases or dust 2 USE AND CARE Take proper care of the charger Keep an eye out for defective connections defects and all other conditions that may affect the device s operation If any damage repair ...

Page 3: ...ctions 4 Specifications 4 Installation 4 Charging Status 5 Electrical Connections 5 Back Pack Installation 5 Warranty 6 Customer Service 6 Disposal 6 EC Declaration of Conformity 7 Drill Template 8 CONTENTS s r er ...

Page 4: ...supplied with charger INPUT POWER 115VAC 1 Amp 115 watts 230VAC 0 5 Amp 115 watts 12VDC 9 AMP 24VDC 4 5 Amp 110 watts OUTPUT Dual Channel 42VDC 1 Amp Charge Rate per Battery Pack Channel CHARGE TIME 6 Hour Nominal OVER CHARGE PROTECTION Charger shuts down if Battery Pack charge current does not drop to 150 milliamps within 9 hours UNDER VOLTAGE DISABLE Charger disabled if battery pack voltage is l...

Page 5: ... AC Models Insert AC plug into the appropriate AC power receptacle The AC input battery charger models are built around a universal 85 260AC 50 60Hz input power supply Only the AC plug determines the input voltage to be 115VAC or 230VAC DC Models Will work with 10 30VDC input Charger is not equipped with a power switch and there is no reason to cycle power ON OFF Charger automatically turns ON whe...

Page 6: ...mproper handling For information please visit www RAMFAN com The customer service department will answer your questions regarding repairs and maintenance for your product as well as regarding spare parts and operation You can also find further information at www RAMFAN com Warranty Customer Service and Advice Disposal Charging devices accessories and packaging should be recycled in an environmenta...

Page 7: ...0 EU EMC Directive 2014 35 EU Low Voltage Directive 2011 65 EU Restriction of Hazardous Substances Directive Standards to which this Conformity is Declared BS EN ISO 13857 2008 Safety Distances BS EN ISO 12100 2010 Safety Machinery BS EN 6100 6 4 2007 A1 2011 EMC Industrial Generic Emission BS EN 6100 6 2 2005 EMC Immunity Industrial Environments Euramco Safety Inc hereby declares that the equipme...

Page 8: ...8 AIR FLOW 261 9m 10 31 191 9mm 7 56in SET BACK 2 FROM WALL MINIMUM Drill Template Half scale size of template ...

Page 9: ...31in 10 2mm 400in 5 6mm 221in ACCURATE BEFORE DRILLING 4 PLACES MAKE SURE THAT DIMENSIONS ARE DRILL FOR 10 OR M5 SCREW FULL SCALE TEMPLATE POWER CABLE DWG NO Euramco Safety Inc R2C DRILL TEMPLATE PART NO DWG R2TEMPLATE Description FIDUCIAL TARGETS ...

Page 10: ...10 NOTES ...

Page 11: ...11 ...

Page 12: ...70 7345 theteam euramco com LUXEMBOURG 1 Rue Edmond Reuter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramco com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590 x114 Fax 1 619 670 7345 theteam euramco com CHINA No 128 HeZhou Road JiaoChuan Street ZhenHai District Ningbo China 315207 Phone 86 574 87979390 Fax 86 574 87979391 saleschina euramco com ...

Reviews: