Raisecom
ISCOM6820-GP (A) Hardware Description
2 Components
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
17
Figure 2-12
Panel of the RPA1302 power module
2.6.3 Interfaces
There is 1 interface on the RPA1302 power module.
Table 2-17 lists the interface on the RPA1302 power module.
Table 2-17
Interface on the RPA1302 power module
Interface
Usage
100–240 V 50/60 Hz
AC power interface/C13 connector socket
2.6.4 LEDs
There are 4 LEDs on the RPA1302 power module.
Table 2-18 lists LEDs on the RPA1302 power module.
Table 2-18
LEDs on the RPA1302 power module
LED
Status
Description
SYS
Green
Power LED
Green: the power supply is working properly.
Off: the device is powered off or powered on improperly.
ALM
Red
Alarm LED
Green: the power supply works abnormally.
Off: the device is not powered on or powered on improperly.
-48V
Green
Output voltage LED
Red: the device DC voltage is output normally.
Off: the device DC voltage is output abnormally.
AC
Green
Power input LED
Red: the device external power is input normally.
Off: the device external power is not input or input abnormally.
Summary of Contents for ISCOM6820-GP
Page 1: ...ISCOM6820 GP A Hardware Description Rel_01 www raisecom com ...