INSTALLATION MANUAL
Gas supply emergency stop
If you smell gas, immediately switch off the gas supply. Turn off the fireplace at the stopcock and
main switch.
Ventilate the room by opening windows and doors. Do not use electrical appliances or switches in
the vicinity of the fireplace. The gas supply may not be reconnected until an authorised heating
and plumbing/gas technician has examined the fireplace and approved it.
NB!
RAIS/ATTIKA recommends 20 mm gas supply pipes for town gas burners.
Safety
It is important that the fireplace is correctly installed in consideration of the environment and people’s
safety. No unauthorised alterations may be made to the fireplace.
The fireplace may not be used if the glass is split, cracked or removed. Do not use the fireplace if the
glass gasket is broken or worn.
This fireplace is designed for use in many different installation situations, which are shown in this
manual. Only flue systems that are CE approved for this product may be used (see the section “flue
system”).
This fireplace is designed for a balanced flue system (air intake and extraction in the same chimney).
Therefore there is no need for an extra air supply for combustion. It is recommended that the air
replacement in the room is adjusted to ensure a pleasant indoor environment. This fireplace can be
installed in an airtight building or in a building with mechanical ventilation, since the gas fireplace
functions in a closed system that does not extract combustion air from the room.
NB!
The fireplace must be installed in fireproofed material. Due to the risk of fire, flammable items
(e.g. furniture) may not be positioned closer than 1000 mm from the front of the glass.
This product is a heating appliance. This means that surfaces become very hot and must not be
touched when the fireplace is in use. It is therefore recommended that an approved screen is
used to protect children, seniors and persons with limited mobility who are in the vicinity of the
fireplace.
If the fireplace is switched off or the fire goes out, wait at least three minutes before lighting it
again.
6 - GB
GB
Summary of Contents for VISIO 4 Series
Page 14: ...INSTALLATION MANUAL 5 Position the bottom grate above the burner 14 GB GB ...
Page 24: ...INSTALLATION MANUAL INSTALLATION MANUAL 1000 1000 150 1000 50 Tunnel models 24 GB GB ...
Page 70: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 70 GB GB ...
Page 71: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 71 GB ...
Page 72: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 72 GB GB ...
Page 73: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 73 GB ...
Page 74: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 74 GB GB ...
Page 75: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY GB 75 GB ...
Page 76: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY 76 GB GB ...
Page 99: ...INSTALLATION MANUAL Flue parts GB 99 GB ...
Page 100: ...INSTALLATION MANUAL 100 GB GB ...
Page 101: ...INSTALLATION MANUAL GB 101 GB ...
Page 102: ...INSTALLATION MANUAL 102 GB GB ...
Page 108: ...INSTALLATION MANUAL 108 GB GB ...