INSTALLATION MANUAL
Installation of fireplace
In this section, you will learn how to install your fireplace.
The control box is connected to the fireplace’s burners. This must be placed in the inspection hatch,
which must be placed in an appropriate place on the installation.
This fireplace has adjustable legs, and these should be set to the desired height before the flue system
is installed. Small adjustments of the legs are possible using the feet. Never make any changes to the
fireplace other than adjusting the height of the legs.
The safety distance from the flue pipe to flammable materials must be least 50 mm. This distance can
be shortened to 25 mm at the side of and under horizontal flue pipes if these are insulated.
The installation space must be equipped with convection openings which have a minimum area of 200
cm
2
. RAIS/ATTIKA recommends an area for convection air above the fireplace of at least 700 cm
2
, and
an area for convection air below the fireplace of at least 500 cm
2
.
There should be free space of at least 50 mm around the entire fireplace to allow convection.
If a shelf is fitted above the fireplace’s opening, there should be free space of at least 150 mm between
the opening and the shelf.
The fitted brackets are used to secure the fireplace to the rear wall.
Two measuring points are positioned above the glass and are used to carry out combustion checks. On
the left, fresh air in, on the right, exhaust air. In cases where national regulations require that control
measurements are taken in the flue pipe and above the fireplace, a measuring spigot is positioned
here.
Installation dimensions
Build a structure of the desired size made from non-flammable materials – the minimum dimensions
for each model is shown in the section.
Dimensional drawings and installation drawings
.
Do not use insulated material (or other material) to fill the void above and at the side of the fireplace.
There must be access to an inspection hatch in the installation.
GB - 19
GB
Summary of Contents for VISIO 4 Series
Page 14: ...INSTALLATION MANUAL 5 Position the bottom grate above the burner 14 GB GB ...
Page 24: ...INSTALLATION MANUAL INSTALLATION MANUAL 1000 1000 150 1000 50 Tunnel models 24 GB GB ...
Page 70: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 70 GB GB ...
Page 71: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 71 GB ...
Page 72: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 72 GB GB ...
Page 73: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 73 GB ...
Page 74: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 74 GB GB ...
Page 75: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY GB 75 GB ...
Page 76: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY 76 GB GB ...
Page 99: ...INSTALLATION MANUAL Flue parts GB 99 GB ...
Page 100: ...INSTALLATION MANUAL 100 GB GB ...
Page 101: ...INSTALLATION MANUAL GB 101 GB ...
Page 102: ...INSTALLATION MANUAL 102 GB GB ...
Page 108: ...INSTALLATION MANUAL 108 GB GB ...