Gas type
(Liquid petroleum gas - LPG)
G30/G31
I3B/P(30)
G30/G31
I3+
G31
I3P(50)
G31
I3P(37)
G31
I3P(30)
Supply Pressure
mbar
30
30 / 37
50
37
30
Nominal Heat Input
Gross (Hs)
kW
14.4
14.4
14.4
14.4
11.5
Nominal Heat Input
Net (Hi)
kW
12.9
12.9
12.9
12.9
10.3
Consumption
m³/hr
0.4
0.4 / 0.51
0.51
0.51
0.41
Burner Pressure
(hot)
mbar
27
27 / 36
36
36
28
Injector Marking
100 Centre, 160 Left, 160 Right
Pilot
G30-ZP2-271 (27.1 inj)
Efficiency Class
1
NOx Class
5
Type
C11 / C31