YOUR NEW GAS FIREPLACE IN GENERAL
NB!
RAIS/ATTIKA recommends 20 mm gas supply pipes for town gas burners .
Gas supply emergency stop
If you smell gas, immediately switch off the gas supply . Turn off the fireplace at the stopcock and
main switch .
Ventilate the room by opening windows and doors . Do not use electrical appliances or switches in
the vicinity of the fireplace . The gas supply may not be reconnected until an authorised heating and
plumbing/gas technician has examined the fireplace and approved it .
Your new gas fireplace in general
This RAIS/ATTIKA product is a highly efficient convection gas fireplace with a sealed combustion chamber
for a balanced flue system . The fireplace has variable heating power and is equipped with a burner which
has been developed using the latest burner technology .
Before installation
All local laws and provisions should be studied before installation . Always check the national building and
gas regulations .
In addition, it should be confirmed that the information on the information plate relating to gas type and
gas pressure is in accordance with the local gas conditions that the fireplace shall be installed under . The
gas supply should be examined to ensure that it can supply the required amount of gas and the required
pressure .
It is recommended that gloves are worn when installing the gas fireplace to avoid fingerprints on glass, etc .
Gas connection
This fireplace may only be installed, adjusted and serviced by an authorised and qualified heating and
plumbing/gas technician . The installation must comply with local and national building and gas regulations,
and the instructions in the installation manual must be followed . The installation manual and user manual
must be left with the customer, who must keep the manuals for later use . The manuals are necessary when
the fireplace is to be serviced .
The pipe on the gas hose has an external diameter of 8 mm . When it has been determined where the
fireplace shall be installed, a gas installation with a stopcock in the vicinity of the fireplace must be executed
to ensure t
hat the gas supply and the fireplace can be connected .
Since this fireplace is equipped with a sealed combustion chamber, a floor plate is not necessary .
Hearths
Follow the guidelines in document J point 3 .40 - 3 .41 concerning hearths .
If the fireplace is connected to bottled gas, it may only be connected to bottle gas that is equipped with a
gas regulator (low pressure regulator) that supplies the correct gas pressure .
Ensure that the balanced flue system is not blocked in any way and is free of vegetation in the form of
trees, bushes, etc .
The glass must always be cleaned on the outside before the fireplace is lit . Fingerprints must be wiped off
as these can burn into the glass .
GB - 5
GB
Summary of Contents for Nexo 100
Page 15: ...DIMENSIONAL DRAWINGS VIVA L GAS Viva L 140 Gas GB 15 GB...
Page 87: ...DECLARATION OF PERFORMANCE GB 87 GB...
Page 88: ...DECLARATION OF PERFORMANCE 88 GB GB...
Page 89: ...DECLARATION OF PERFORMANCE GB 89 GB...
Page 90: ...DECLARATION OF CONFORMITY 90 GB GB...
Page 91: ...DECLARATION OF CONFORMITY GB 91 GB...
Page 92: ...DECLARATION OF CONFORMITY 92 GB GB...
Page 94: ...94 GB GB...