INSTALLATION DISTANCES - NEXO GAS
Installation distances
To clarify whether the gas fireplace shall be installed next to a flammable wall, please contact your building
architect or your local building authority .
It must be ensured that flammable items (e .g . furniture) are never positioned closer to the fireplace than
the minimal permitted distance stated in the following tables . Failure to comply with the minimal permitted
distance may lead to a fire .
We recommend a minimum distance of 75 mm to non-flammable material in consideration of servicing
and installation work .
Nexo Gas - at flammable wall
Normal installation - right-angle
Without side glass
Minimum distance to flammable material
Non-insulated flue
Minimum distance to furniture
700 mm
Rear (wall)
50 mm
From side to wall
250 mm
Established:
Designer: Project manager:
Format:
Approved:
Drawing no.:
Revision:
Project:
Drawing name:
INDUSTRIVEJ 20, 9900 FREDERIKSHAVN, DENMARK
Phone +45 98 47 90 33 - Fax +45 98 47 92 91
E-mail: [email protected] - Homepage: www.rais.dk
Corrections:
D M Y
ksj
Nexo Gas - Retvinklet opstilling
01-04-2019
A3
10-6554
10
250
50
19
8
223
34 - GB
GB
Summary of Contents for Nexo 100
Page 15: ...DIMENSIONAL DRAWINGS VIVA L GAS Viva L 140 Gas GB 15 GB...
Page 87: ...DECLARATION OF PERFORMANCE GB 87 GB...
Page 88: ...DECLARATION OF PERFORMANCE 88 GB GB...
Page 89: ...DECLARATION OF PERFORMANCE GB 89 GB...
Page 90: ...DECLARATION OF CONFORMITY 90 GB GB...
Page 91: ...DECLARATION OF CONFORMITY GB 91 GB...
Page 92: ...DECLARATION OF CONFORMITY 92 GB GB...
Page 94: ...94 GB GB...