Installation Instructions

 

The following pages give instructions for the safe and proper installation of this heating 
appliance in the UK. These instructions cover the basic principles of installation, 
although some details may need slight modification to suit particular local site conditions. 
In all cases the installation must comply with current UK Building Regulations, Local 
Authority Byelaws and other specifications or regulations as they affect the installation of 
the stove. 
Please note that it is a legal requirement under England and Wales Building Regulations 
that the installation of the stove is either carried out under local Authority Building 
Control approval or is installed by a Competent Person registered with a Government 
approved Competent Persons Scheme. HETAS operate such a scheme and a listing of 
their registered Competent Persons can be found on their website at www.hetas.co.uk. 

It should be noted that the current Building Regulations requirements are given in 
Approved Document J. These requirements may also be met by adopting the relevant 
recommendations given in British Standards BS 8303, BS 6461 and BS 7566.

 

WARNING.  Health and Safety Advice Notice.

 

The installation of this heating appliance is governed by the Health and Safety at Work 
Act 1974. it is the responsibility of the installer to ensure that all requirements of this Act 
are met during the installation works. Attention is drawn in particular to the following: 

Handling: 

The appliance is a heavy item and adequate facilities must be available 
for loading, unloading and site handling. 

Fire Cement:  Some types of fire cement are caustic and should not be allowed to come 

into contact with the skin. Protective gloves should be worn when 
handling fire cement. In case of contact with the skin, wash immediately 
with plenty of water. 

Asbestos: 

This stove contains no asbestos. If there is a possibility of disturbing any 
asbestos in the course of the installation, then please seek specialist 
guidance and use appropriate protective equipment. 

Metal Parts:  When installing or servicing this stove care should be taken to avoid the 

possibility of personal injury.

 

Important Warning  ­  Preparatory Work and safety Checks:

 

· 

This stove must not be installed into a chimney which serves any other heating 
appliance.

 

· 

There must not be an extractor fan fitted in the same room as the stove, as this can 
cause the stove to emit fumes into the room.

 

· 

If this appliance is installed into an existing chimney, the chimney must first be 
swept and examined for soundness and suitability, before the appliance is installed 
(see also section headed ‘Chimney’).

Summary of Contents for 800

Page 1: ...IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the door seal and seal...

Page 2: ...ENGLISH RAIS manual for Rais 800 2...

Page 3: ...IBLE WALL 12 13 INSTALLATION DISTANCE TO NON COMBUSTIBLE WALL 14 15 FOR THE INSTALLER 17 OPERATING INSTRUCTIONS 18 FUEL 18 DRYING AND STORAGE 19 REGULATION OF COMBUSTION AIR 19 USING THE WOOD BURNING...

Page 4: ...the stove s production number We therefore recommend that you note down the number in the table below The production number is located in the top of the convection box Warranty Your Rais wood burning...

Page 5: ...of wood when fuelling kg Based on 2 3 logs of wood approx 25cm 1 5 Min uptake Min draught Pascal 12 Weight kg 130 Efficiency 77 Particles after NS3058 3059 g kg 2 7 Dust measured according to Din mg...

Page 6: ...convection stoves This means that the stove s back and side panels are not over heated Convection means that there is a circulation of air which ensures that the heat is distributed more evenly throu...

Page 7: ...stallation of this heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met during the inst...

Page 8: ...r must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and should have been swept clean immediately before the installation of the...

Page 9: ...on e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2 flues...

Page 10: ...ets which may be connected with suit able air ducts to other rooms Building Regulations Approved Document J gives specific guidance on the required permanent ventilation into the room for combustion a...

Page 11: ...are available to order from your local Rais dealer stockist Using a spirit level against the door and body of the stove ensure that the stove is perfectly level and make adjustments using the levellin...

Page 12: ...ENGLISH RAIS manual for Rais 800 12 Insulation ability such as Aqua panel coefficient of thermal conductivity 0 36 W mk or better Please use metal stud...

Page 13: ...ENGLISH RAIS manual for Rais 800 13...

Page 14: ...ENGLISH RAIS manual for Rais 800 14 Insulated flue pipe from the stove...

Page 15: ...ENGLISH RAIS manual for Rais 800 15...

Page 16: ...on a wooden floor it must be covered with a non combustible material at least 12mm thick in accordance with UK Building Regulations Approved Document J to a distance of 300 mm in front of the stove a...

Page 17: ...iance connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user Read the later parts of this manual for guidance on care r...

Page 18: ...combustion chamber minus 50 60 mm Stoking with wet firewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 70 water and is thoroughly unsuitable for...

Page 19: ...er and is pre heated through the side channels and then emitted as hot scavenging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at the t...

Page 20: ...is almost closed meaning that there is a minimal air intake Position 2 Push the lever until the first click This position gives full secondary air During normal use the lever is set between position 1...

Page 21: ...tove gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPORTANT War...

Page 22: ...r to the fully open position Tips before firing up Open a door or window close to the wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a screwed up pi...

Page 23: ...bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes or when the f...

Page 24: ...chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste or recycle on the garden REMEMBER Never re...

Page 25: ...other end is lowered and the baffle plate turned a little Gently take out the baffle plate Remove the smoke conductor Lift one side up and lower the other Gently lower the smoke conductor and remove i...

Page 26: ...raught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty smoke channe...

Page 27: ...If spare parts other than those recommended by RAIS are used the warranty is voided All replacement spare parts can be purchased from your RAIS distributor stockist See the following spare parts diagr...

Page 28: ...ENGLISH RAIS manual for Rais 800 28 Spare parts diagram Rais 800 Position Ref Quantity Item No Description 1 1 5401090 95 Door 2 1 54000990 95 Air system 3 1 5302200 Fire brick set 4 5305500 Seal set...

Page 29: ...ENGLISH RAIS manual for Rais 800 29...

Page 30: ...ENGLISH RAIS manual for Rais 800 30...

Page 31: ...ENGLISH RAIS manual for Rais 800 31...

Page 32: ...GLISH RAIS manual for Rais 800 32 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk June 20...

Reviews: