2. Mount the System
Use screws (not supplied) to secure the Ultrefiner II bracket assembly to the
8
10.0 in (25.4 cm)
4.7 in (11.9 cm) without cover
5.0 in (12.7 cm) with cover
7.0 in (17.8 cm) Mimimum required
from mounted wall for cover on / off
15.1 in (38.4 cm)
12.3 in (31.3 cm)
12.5 in (31.8 cm) with Cover
10.0 IN
(25.4 CM)
3.5 IN (8.9CM) MINIM
UM
DIST
ANCE REQUI
RED ABOVE THE
UL
TREFINER II
UNIT
13.0 IN (33.0
CM) MINIM
UM
DIST
ANCE REQUI
RED BEL
OW
THE MOUNTING HOLES
USING PHILIPS OFFSET
SCREWDRIVER
TO SECURE THE ULTREFINER II
Helpful Tip: The proper drill bit should be selected
according to the type of material at the desired
installation location.
Figure 6
Figure 7
3. Push-IN Tubing Connections:
F
or all tubing connections on the system, follow these steps to be sure that
the tube is properly installed in the fitting:
•Slightly lubricate the tube with silicone before pushing into the fitting.
•It is important that the tube be fully inserted to the proper depth. You may
measure from the end of the tube & use a marker to put a line as a guide.
•See figure 8 for proper installation practice & depth on each connection.
!
Important Note: Ultrefiner II tank port and
outlet port use double o-rings. If you see a leak
from one of these ports, remove the tube and
look into the port to see that both o-rings are
properly aligned, leaving a clear path for the
tubing. If one of the o-rings is moved out of posi-
tion, it may block tube insertion. Please push it
back into position before inserting the tube.